User Manual

Table Of Contents
GENERAL DATA
2-5
2.1.4. DUCT TYPE (RAD-18RPA/25RPA/35RPA/50RPA)
INDOOR
Unit
RAD-18RPA
RAD-25RPA
RAD-35RPA
RAD-50RPA
Nominal capacity adjustable
-
-
-
-
Nominal Cooling capacity (min - max)
kW
1.8 (0.9~2.5)
2.5 (0.9-3.0)
3.5 (0.9-4.0)
5.0 (0.9-5.6)
Cooling sensible capacity
kW
-
2.0
2.5
3.8
Nominal Heating capacity (min - max)
kW
2.5 (0.9~3.2)
3.5 (0.9-5.5)
4.8 (0.9-6.6)
6.0 (0.9-7.5)
Noise level cooling (sound pressure)
(SL / L / M / H)
dB(A)
29/31/34/36
29/31/34/36
29/31/34/36
29/32/35/38
Noise level heating (sound pressure)
(SL / L / M / H)
dB(A)
27/30/33/37
27/30/33/37
27/30/33/37
29/32/35/38
Noise level (sound power)
dB(A)
N/A
57
57
58
Air flow cooling mode (SL / L / M / H)
m3/h
330/372/438/492
330/390/450/510
330/390/450/510
330/360/450/510
Air flow heating mode (SL / L / M / H)
m3/h
330/372/450/552
360/420/480/600
360/420/480/600
360/420/480/630
Fan Motor
W
20
20
20
20
Drain pump pressure lift
cm
30 max
30 max
30 max
30 max
Static pressure (SL / L / M / H)
(nominal conditions SP 00)
Pa
-
-
-
-
Dehumidification
l/h
1.4
1.4
1.6
2.8
Included drain pump
yes
yes
yes
yes
Max. height available for drain pump
(RAD/RAI only)
300
300
300
300
Dimensions (H x W x D)
mm
235x750x400
235x750x400
235x750x400
235x750x400
Panel dimensions (H x W x D)
mm
-
-
-
-
Weight
kg
16.0
16.0
16.0
16.0
Colour (Munsell Code)
-
-
-
-
Condensate Drain
mm
φ16
φ16
φ16
φ16
Panel weight
kg
-
-
-
-
Panel reference
-
-
-
-
Color of the panel (RAL)
-
-
-
-
Running current
A
2.56~2.35 /
3.2~2.92
3.19~2.93 /
4.45~4.08
5.69~5.22 /
7.81~7.15
9.10~8.37 /
9.87~9.05
Power supply
35V DC from
outdoor
35 V DC from
outdoor unit
35 V DC from
outdoor unit
35 V DC from
outdoor unit
Cable section
mm²
N/A
N/A
N/A
N/A
Piping diameter (Liq / Gas)
1/4" / 3/8"
1/4" / 3/8"
1/4" / 3/8"
1/4" / 1/2"
Drain diameter (ext)
mm
φ16
φ16
φ16
φ16
Remote control (optional only) *
SPX-RCKA /
SPX-RCDA
SPX-RCKA /
SPX-RCDA
SPX-RCKA /
SPX-RCDA
SPX-RCKA /
SPX-RCDA
Filter
ACL Filter
-
-
-
-
Dimensions (H x W x D)
mm
-
-
-
-
Pre-filter (Standard / Optional)
Washable/-
Washable/-
Washable/-
Washable/-
*more information regarding remote control can be found in Chapter 9
NOTE:
1. The nominal cooling and heating capacity is the
combined capacity of the HITACHI standard split
system, and are based on the ISO 5151.
2. The Sound Pressure Level is based on the following
conditions:
- 0.8 meter beneath indoor height center
- 1.5 meter from Discharge grille
The above data was measured in an anechoic
chamber. Please take into consideration reflected
sound of your specific site
Operation Conditions
Cooling
Heating
Indoor Air Inlet Temperature
dB
27.0 °C
20.0 °C
WB
19.0 °C
Outdoor Air Inlet Temperature
dB
35.0 °C
7.0 °C
WB
6.0 °C
Piping Length: 5.0 meters; Piping Lift: 0 meter
dB: Dry Bulb; WB: Wet Bulb