2.1.6. FLOOR TYPE (RAF-25RPA/35RPA/50RPA)
INDOOR
Unit
RAF-25RPA
RAF-35RPA
RAF-50RPA
Nominal capacity adjustable
no
no
no
Nominal Cooling capacity (min - max)
kW
2.50 (0.90 - 3.10)
3.50 (1.10 - 4.20)
5.00 (1.90 - 5.20)
Cooling sensible capacity
kW
2.3
2.9
3.8
Nominal Heating capacity (min - max)
kW
3.40 (0.90 - 4.40)
4.20 (1.10 - 5.20)
6.00 (2.20 - 7.30)
Noise level cooling (sound pressure)
(SL / L / M / H)
dB(A)
23/26/32/40
25/29/35/42
25/30/37/46
Noise level heating (sound pressure)
(SL / L / M / H)
dB(A)
23/27/33/40
26/30/35/42
25/30/37/47
Noise level (sound power)
dB(A)
54
56
60
Air flow cooling mode (SL / L / M / H)
m
3
/h
378/462/540
400/485/600
430/530/650
Air flow heating mode (SL / L / M / H)
m
3
/h
408/498/600
440/525/600
470/570/720
Fan Motor
W
25
25
25
Drain pump pressure lift
cm
-
-
-
Static pressure (SL / L / M / H)
(nominal conditions SP 00)
Pa
-
-
-
Dehumidification
l/h
1.4
1.6
2
Included drain pump
-
-
-
Max. height available for drain pump
(RAD/RAI only)
-
-
-
Dimensions (H x W x D)
mm
600x760x235
600x760x235
600x760x235
Panel dimensions (H x W x D)
mm
-
-
-
Weight
kg
14
14
14
Colour (Munsell Code)
PURE WHITE (N9.25)
Condensate Drain
mm
φ16
φ16
φ16
Panel weight
kg
-
-
-
Panel reference
-
-
-
Color of the panel (RAL)
-
-
-
Running current
A
3.43/4.11
4.30/4.81
6.63/7.29
Power supply
35 V DC from outdoor
unit
35 V DC from outdoor
unit
35 V DC from outdoor
unit
Cable section
mm²
0.75x2
0.75x2
0.75x2
Piping diameter (Liq / Gas)
1/4” - 3/8”
1/4” - 3/8”
1/4” - 1/2”
Drain diameter (ext)
mm
φ16
φ16
φ16
Remote control (standard/optional) *
RAR-5E2/SPX-RCDB
RAR-5E2/SPX-RCDB
RAR-5E2/SPX-RCDB
Filter
ACL Filter
Nano Titanium
Nano Titanium
Nano Titanium
Dimensions (H x W x D)
mm
48x243x8
48x243x8
48x243x8
Pre-filter (Standard / Optional)
Stainless/-
Stainless/-
Stainless/-
*more information regarding remote control can be found in Chapter 9
NOTE:
1. The nominal cooling and heating capacity is the
combined capacity of the HITACHI standard split
system, and are based on the ISO 5151.
2. The Sound Pressure Level is based on the following
conditions:
- Half height of the unit
- 1 meter from Discharge grille
The above data was measured in an anechoic
chamber. Please take into consideration reflected
sound of your specific site
Operation Conditions
Cooling
Heating
Indoor Air Inlet Temperature
dB
27.0 °C
20.0 °C
WB
19.0 °C
Outdoor Air Inlet Temperature
dB
35.0 °C
7.0 °C
WB
6.0 °C
Piping Length: 5.0 meters; Piping Lift: 0 meter
dB: Dry Bulb; WB: Wet Bulb