User Manual

Table Of Contents
GENERAL DATA
2-8
2.1.7. MONOZONE OUTDOOR (RAC-25NPA/35NPA/50NPA)
OUTDOOR
UNIT
RAC-25NPA
RAC-35NPA
RAC-50NPA
Minimum / Maximum indoor
units connectable
-
-
-
Minimum / Maximum connected
capacity
2.5kW
3.5kW
5.0kW
Nominal Cooling capacity
(min - max)
kW
REFER TO INDOOR
REFER TO INDOOR
REFER TO INDOOR
Nominal Heating capacity
(min - max)
kW
REFER TO INDOOR
REFER TO INDOOR
REFER TO INDOOR
Nominal cooling power input
(min - max)
kW
RAI -0.695 (0.155-1.050)
RAD - 0.695 (0.155-1.050)
RAI - 1.100 (0.155-1.280)
RAD - 1.240 (0.155-1.280)
RAI - 1.990 (0.155-2.200)
RAD - 2.000 (0.155-2.060)
Nominal heating power input
(min - max)
kW
RAI -0. 940 (0.155-1.400)
RAD - 0.970 (0.115-1.400)
RAI - 1.360 (0.115-1.920)
RAD - 1.700 (0.115-1.920)
RAI - 2.160 (0.155-2.700)
RAD - 2.300 (0.115-2.530)
EER / COP
RAI - 3.60 / 3.72
RAD -3.60 / 3.61
RAI - 3.18 / 3.53
RAD -2.82 / 2.82
RAI - 2.51 / 2.87
RAD -2.50 / 2.61
SEER / SCOP
RAI 5.7 / 3.8
RAD - 5.1 / 3.8
RAI 5.8 / 3.8
RAD - 5.1 / 3.8
RAI 5.2 / 3.8
RAD - 4.7 / 3.8
Energy class (SEER/SCOP)
RAI A+ / A
RAD - A / A
RAI A+ / A
RAD - A / A
RAI - A / A
RAD - B / A
Noise level cooling
(sound pressure)
dB(A)
46
47
50
Noise level heating
(sound pressure)
dB(A)
46
49
52
Noise level (sound power)
dB(A)
65
65
65
Air flow (Cooling / Heating)
m3/h
1620/1620
1620/1620
2160/2160
Static pressure
(nominal conditions, maximum)
Pa
-
-
-
Dimensions (H x W x D)
mm
570x750x280
570x750x280
650x850x298
Weight
kg
38.0
38.0
45.0
Colour (Munsell Code)
Power supply
AC 220-240V/1ph/50Hz
AC 220-240V/1ph/50Hz
AC 220-240V/1ph/50Hz
Recommended fuse size
A
16
16
16
Starting current
A
3.2/4.3
3.2/4.3
9.9
Running current
A
RAI: 3.20-2.93 / 4.30-3.96
RAD: 3.19-2.93 / 4.45-4.08
RAI: 5.05-4.63 / 6.24-5.72
RAD: 5.69-5.22 / 7.81-7.15
RAI: 9.1-8.37 / 9.879.05
RAD: 9.1-8.37 / 9.87-9.05
Cable section
mm2
2
2
2
Interconnection between indoor
unit and outdoor unit
mm2
2
2
2
Piping diameter (Liq / Gas)
1/4" / 3/8"
1/4" / 3/8"
1/4" / 1/2"
Minimum piping length
m
5.0
5.0
5.0
Maximum piping
length / height difference
m
20 / 10
20 / 10
20 / 10
Current quantity of refrigerant /
Chargeless
kg
1.15
1.15
1.40
Chargeless / Additional
refrigerant charge
m / g/m
20/-
20/-
20/-
Working range (cooling /
heating)
°C
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
Refrigerant
R410A
R410A
R410A
Condenser Fan
Propeller Fan
Compressor
Type
2 Cylinder Rotary
2 Cylinder Rotary
2 Cylinder Rotary
Oil Type
HAF68D1/68HES-H
HAF68D1/68HES-H
HAF68D1/68HES-H
Oil Charge
ml
380
380
480
Coil
Resistance
1.05 at 20C
1.05 at 20C
1.05 at 20C
1.28 at 75C
1.28 at 75C
1.28 at 75C
Quantity
1
1
1
NOTE:
1. The nominal cooling and heating capacity is the combined capacity of
the HITACHI standard split system, and are based on the ISO 5151.
2. The Sound Pressure Level is based on the
following conditions:
- 1.4 meter from Discharge grille
The above data was measured in an
anechoic chamber. Please take into
consideration reflected sound of your
specific site
Operation Conditions
Cooling
Heating
Indoor Air Inlet Temperature
dB
27.0 °C
20.0 °C
WB
19.0 °C
Outdoor Air Inlet Temperature
dB
35.0 °C
7.0 °C
WB
6.0 °C
Piping Length: 5.0 meters; Piping Lift: 0 meter