WORKING RANGE
5-2
5.1. POWER SUPPLY
Working Voltage
198V ~ 264V
Voltage Imbalance
Within a 3% Deviation from Each Voltage at the Main Terminal of
Outdoor Unit
Starting Voltage
Higher than 85% of the Rated Voltage
5.2. WORKING RANGE
5.2.1. MONO SPLIT - PREMIUM
Applicable models:
PREMIUM
RAC-18WSA
RAC-18WSAN
RAC-25WSA
RAC-25WSAN
RAC-35WSA
RAC-35WSAN
The temperature range is indicated in the following table.
Cooling
Heating
working range
min (
o
C)
max (
o
C)
rated (
o
C)
working range
min (
o
C)
max (
o
C)
rated (
o
C)
outdoor
22
43
35
outdoor
-20
21
7
indoor
16
32
27
indoor
16
32
20
Cooling
0
10
20
30
40
50
0
10 20 30 40
Indoor temperature
Ambient temperature
Heating
-20
-10
0
10
20
30
40
50
-10
0 10 20 30 40
Indoor temperature
Ambient temperature
Indoor Temperature
Indoor Temperature
Ambient Temperature
Ambient Temperature
Indoor Temperature
COOLING
HEATING