User Manual

Table Of Contents
GENERAL DATA
2-22
2.2.12. WALL TYPE (RAC-50WPA/60WPA/70WPA)
OUTDOOR
UNIT
RAC-50WPA
RAC-60WPA
RAC-70WPA
Minimum / Maximum indoor units
connectable
-
-
-
Minimum / Maximum connected
capacity
-
-
-
Nominal Cooling capacity (min - max)
kW
5.0(0.9-5.2)
6.10 (0.9-6.5)
7.00 (1.5-8.00)
Nominal Heating capacity (min - max)
kW
6.00 (0.9-8.1)
6.80 (0.9-8.5)
8.00 (1.5-9.2)
Nominal cooling power input (min -
max)
kW
1.56 (0.155-1.900)
1.85 (0.155-2.300)
2.17 (0.200-2.820)
Nominal heating power input (min -
max)
kW
1.66(0.155-2.010)
1.88 (0.120-2.550)
2.2 (0.200-2.970)
EER / COP
3.21/3.61
3.30 /3.62
3.23/3.64
SEER / SCOP
6.1/4.3
6.0/4.0
6.8/4.4
Energy class (SEER/SCOP)
A+/A+
A+/A+
A+/A+
Noise level cooling (sound pressure)
dB(A)
50
50
52
Noise level heating (sound pressure)
dB(A)
52
53
54
Noise level (sound power)
dB(A)
65
66
67.0
Air flow (Cooling / Heating)
m
3
/h
2160/2160
2160/2160
2820/2820
Static pressure (nominal conditions,
maximum)
Pa
-
-
-
Dimensions (H x W x D)
mm
650x850x298
650x850x298
800x850x298
Weight
kg
45.0
45.0
55.0
Colour (Munsell Code)
Beige (5Y 7/2)
Power supply
220-230V , 1Ph , 50Hz
220-230V , 1Ph , 50Hz
220-230V , 1Ph , 50Hz
Recommended fuse size
A
16
20
30
Starting current
A
10.0
8.5
10.0
Running current
A
7.15-6.56/7.60-7.00
8.50-7.80/8.60-7.90
9.95~9.10 / 10.10~9.30
Cable section
mm
2
Ø2.0
2.500
2.500
Interconnection between indoor unit
and outdoor unit
mm
2
Ø1.6 OR Ø2.0
2x2.5 + 2x1.6 or 2.0
2x2.5 + 2x1.6 or 2.0
Piping diameter (Liq / Gas)
1/4" / 1/2"
1/4" / 1/2"
1/4" / 5/8"
Minimum piping length
m
3.0
3.0
3.0
Maximum piping length / height
difference
m
20 / 10
30 / 20
30 / 20
Current quantity of refrigerant /
Chargeless
kg
1.65
1.65
1.85
Chargeless / Additional refrigerant
charge
m / g/m
8/10
30 / chargeless
30 / chargeless
Working range (cooling / heating)
°C
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
Refrigerant
R410A
R410A
R410A
Condenser Fan
Propeller Fan
Compressor
Type
2-Cylinder Rotary
2-Cylinder Rotary
2-Cylinder Rotary
Oil Type
HAF68D1
HAF68D1
HAF68D1
Oil Charge
ml
480
480
580
Coil Resistance
1.767 at 20C
1.298 at 20C
1.298 at 20C
2.1649 at 75C
1.767 at 75C
1.767 at 75C
Quantity
1
1
1
NOTE:
1. The Sound Pressure Level is based on the following conditions:
- 1 meter from the unit front surface and 1 meter from floor level
The above data was measured in an anechoic chamber. Please take into consideration reflected sound of your specific
site