For More Precise Control For General Purpose Use Hitachi Industrial Equipment Systems Co., Ltd.
SJ700 Series Line up For More Precise Control SJ700B For General Purpose Use High starting Torque, Powerful Drive and easy setting Trip avoidance function High starting Torque Over current & voltage suppress function Improved Sensorless Vector Control and Auto Tuning produce high starting torque of 200% or more at 0.3Hz.*1 Easy setup of motor constants Ideal for applications which need high torque, such as cranes, extruders and lifts.
High performance, powerful functions, yet user friendly. Programming [EzSQ: Easy Sequence] function Inverter control by Built-in Programming function Item Language Spec Language type I/O function Sequence operation is realized by downloading to an inverter a program created with Hitachi's EzSQ software. Tailor inverter operation to meet changing process requirements, and replace separate PLCs in some cases. By simplifying or eliminating external hardware, signficant cost savings can be achieved.
Ease of Maintenance Easy Operation Easy-removable construction for maintenance User selection of Displayed Parameters Field replacement of cooling fan(s) and DC bus capacitors can be accomplished in a fraction of the time. Using Logic terminal move to SJ700 without wiring change. Read SJ300 Parameter by SRW remote operator and write them in to SJ700 Data comparison function Allows display of only parameters changed from default.
Global standards Versatile Functions Conformity to global standards Instantaneous Power Failure Disregard Function CE, UL, c-UL, C-Tick approvals. The SJ700 ignores instantaneous power failure when power fluctuation happens frequently, as long as DC bus voltage remains higher than under-voltage trip level. Emergency stop Logic input & output Terminal apply sink & source logic Wide Input power voltage range Input voltage 240V for 200V class and 480V for 400V class as standard.
STANDARD SPECIFICATIONS SJ700 Series 3-phase 200V class Model SJ700- JP Version 004LFF2 007LFF2 015LFF2 022LFF2 037LFF2 055LFF2 075LFF2 110LFF2 150LFF2 185LFF2 220LFF2 300LFF2 370LFF2 450LFF2 550LFF2 US Version 004LFUF2 007LFUF2 015LFUF2 022LFUF2 037LFUF2 055LFUF2 075LFUF2 110LFUF2 150LFUF2 185LFUF2 220LFUF2 300LFUF2 370LFUF2 450LFUF2 550LFUF2 Enclosure (*1) IP20 Applicable motor (4-pole, kW(HP)) (*2) Rated capacity (kVA) Output Ratings 0.4(1/2) 0.75(1) 30(40) 37(50) 45(60) 55(75) 200V 1.
STANDARD SPECIFICATIONS SJ700B Series 3-phase 400V class Model SJ700B- 110HFF 150HFF 185HFF 220HFF 300HFF Enclosure (*1) Applicable motor (4-pole, kW(HP)) (*2) Rated capacity (kVA) Output Ratings 550HFF 750HFF 900HFF 1100HFF 1320HFF 1600HFF 75(100) 90(125) 110(150) 132(150) 160(220) IP00 15(20) 22(30) 30(40) 37(50) 400V 18.5(25) 45(60) 55(75) 15.2 20.0 25.6 29.7 39.4 48.4 58.8 72.7 93.5 110.8 135.1 159.3 200.9 480V 18.2 24.1 30.7 35.7 47.3 58.1 70.6 87.2 112.
SPECIFICATIONS General Specifications General Specifications Items Control method Line to line sine wave pulse-width modulation (PWM) control Frequency accuracy Frequency resolution Digital: ±0.01% of the maximum frequency, Analog: ±0.2%(25±10˚C) Digital setting: 0.
DIMENSIONS SJ700-004037 LFUF2, LFF2 SJ700-007040HFEF2, HFUF2, 007037HFF2 SJ700-055110 LFUF2,LFF2 /HFEF2, HFUF2,HFF2 SJ700B-110150HFF SJ700-150220 LFUF2,LFF2 /HFEF2, HFUF2,HFF2 SJ700B-185300HFF SJ700-300 LFUF2,LFF2 /HFEF2, HFUF2, HFF2 SJ700B-370HFF SJ700-370450 LFUF2,LFF2 SJ700-370550 HFEF2, HFUF2,HFF2 SJ700B-450750HFF SJ700-550 LFUF2,LFF2 [ Unit : mm(inch)] Inches for reference only. * Please refer to page 30 for detailed information about compatibility with SJ300.
DIMENSIONS SJ700-750, HFEF2, HFUF2, HFF2 SJ700B-, 1100HFF 2- 12( 0.47) 32.5 80 (12.8) (3.15) Exhaust 79(3.11) 357(14.06) 670(26.38) 700(27.56) Digital Operator Air intake 270(10.63) 2-12(0.47) 300(11.81) 390(15.35) SJ700-1100HFF2 SJ700B-1320 2- 12( 0.47) 62.5 80 (2.46) (3.15) Exhaust 480(18.90) 740(29.13) 710(27.95) 79(3.11) Digital Operator Air intake 270(10.63) 2-12(0.47) 380(14.96) 480(18.90) [ Unit : mm(inch)] Inches for reference only.
DIMENSIONS SJ700-1850,2200HFE2 2-M12 Eyebolts 15(0.59) 3- 15(0.59) Attachment DCreactor(DCL-H-185-H-R),(DCL-H-220-H-R) 305 150 Exhaust W Digital Operator 995(39.17) 965(37.99) H X 230 11x18 245 18 200 25 57.5 (22.63) 15 (0.59) 50 15(0.59) 290(11.41) 290(11.41) Model DCL-H-185-H-R DCL-H-220-H-R 4-M12 Screw Holes For Eyebolts 695(27.36) 2-M12 Eyebolts 15(0.59) SJ700-3150HFE2 Downward details drawing Air Intake 370(14.56) 57.5(2.26) 3- 15(0.
OPERATION and PROGRAMMING SJ700 and SJ700B Series can be easily operated with the digital operator provided as standard. The digital operator can also be detached and can be used for remote-control. Operator with copy function (WOP) and digital operator with potentiometer are also available as options. Parameter Display Power LED Lights when the power input to the drive is ON. Displays frequency, motor current, rotational speed of the motor, and an alarm code.
FUNCTION LIST MONITORING FUNCTIONS and MAIN PROFILE PARAMETERS Monitor Mode Code d001 d002 d003 d004 Output frequency monitor Output current monitor Rotation direction minitoring Process variable (PV), PID feedback monitor d005 Intelligent input terminal status d006 Intelligent output terminal status d007 d008 d009 d010 d012 d013 d014 d015 d016 d017 d018 d019 Scaled output frequency monitoring Actual-frequency monitoring Torque command monitoring Torque bias monitoring Torque monitoring Output volt
= Allowed V/f Characteristic Multispeed operation and Jogging Analog input and others Code DC Braking Frequency Upper/Lower Limit and Jump Frequency PID Control 0.00 0.00 0. 100. 01 31. 00 00 0.00 0.00 0.00 0.00 0.00 0. 100. 01 31. 00 00 0.00 0.00 0.00 Multispeed 1-15 setting 0.0 or “start frequency” to “n-th maximum frequency” (Hz) 0.00 0.00 0.00 0.00 Jog frequency setting "Start frequency" to 9.
= Allowed Acceleration and deceleration Operation-target frequency Acceleration and deceleration External frequency adjustment Code Function Name Monitored data or setting A094 Select method to switch to Acc2/Dec2 profile 00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only when rotation is reversed) A294 Select method to switch to Acc2/Dec2, 2nd motor 00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only when rotation is reversed) A095 A295 A09
= Allowed Free setting of V/f characteristic Others Window comparator Non-stop operation at momentary power failure Torque limitation Others software Overload restriction and overcurrent restraint lock Code 15 Function Name Monitored data or setting b028 Active frequency matching, scan start frequency SJ700: 0.20 x "rated current" to 2.00 x "rated current" (A) < 75kW and over:0.20 x 1.50 > SJ700B: 0.20 x "rated current" to 1.
= Allowed Others Free setting of V/f characteristic Code b112 b113 b120 b121 b122 b123 b124 b125 b126 b127 b130 b131 b132 b133 b134 Function Name Free-setting V/f frequency (7) Free-setting V/f voltage (7) Brake control enable Brake wait time for release Brake wait time for acceleration Brake wait time for stopping Brake wait time for confirmation Brake release frequency setting Brake release current setting Braking frequency Overvoltage suppression enable Overvoltage suppression level Acceleration and
C GROUP: INTELLIGENT TERMINAL FUNCTIONS Function Name Monitored data or setting -FE(CE) -FU(UL) -F(JP) Rated current of inverterx 1..
= Allowed other Input terminal response Output terminal operation function Code C149 C150 C151 C152 C153 C154 C155 C156 C157 C158 C159 C160 C161 C162 C163 C164 C165 C166 C167 C168 C169 Function Name Logical output signal 3 selection 2 Logical output signal 3 operator selection Logical output signal 4 selection 1 Logical output signal 4 selection 2 Logical output signal 4 operator selection Logical output signal 5 selection 1 Logical output signal 5 selection 2 Logical output signal 5 operator selection L
P GROUP: EXPANSION CARD FUNCTIONS Output terminal operation function Code P001 P002 P011 P012 P013 P014 P015 P016 P017 P018 P019 P020 P021 P022 P023 P024 P025 P026 P027 P028 P029 P031 P032 P033 P034 Monitored data or setting 00 (as indicated by the sign), 01 (depending on the operation direction) 00 00 00 00 00 (disabling the mode), 01 (digital operator), 02 (input via O2 terminal) -200. to +200. (%) 00 0. 00 00 0. 00 00 0. 00 00 0.
OPERATOR Operator, Cable 4X-KITmini (For combination with OPE-SR mini) Operator Model Potentiometer OPE-SR mini OPE-SBK OPE-SR WOP SRW-0EX *1 Remote Control Copy function Applied Cable ICS-11m ICS-33m *1) Production has been stopped. Screw You can mount the keypad with the potentiometer for a NEMA1 rated installation. Panel The kit also provides for External removing the potentiometer Gasket knob to meet NEMA 4X Front Cover requirements,as shown (part no.4X-KITmini).
TERMINALS Main Circuit Terminals Terminal Description Terminal Symbol Terminal Symbol Terminal Name R(L1), S(L2), T(L3) Main power supply input terminals U(T1), V(T2), W(T3) Inverter output terminals PD(+1), P(+) DC reactor connection terminals P(+), RB(RB) External braking resistor connection terminals Screw Diameter and Terminal Width W:Terminal width External braking unit connection terminals (G) Ground connection terminal R0 (R0), T0 (T0) Model SJ700 W Terminal Name P(+), N(-) Grou
TERMINALS Control Circuit Terminals Terminal Description Name Symbol Power Supply Common Terminal for Analog Power Source Common terminal for H, O, O2, OI, AM, and AMI. Do not ground. H Power Source for Frequency Setting Power supply for frequency command input Analog Monitor Output Monitor Output Power Supply Digital Run Command Common Terminal Digital Analog Open Collector Output State Analog Input Sensor State/ Alarm Relay Output DC 10V, 20mA max.
PROTECTIVE FUNCTIONS Name Display on remote operator/copy unit Display on digital operator Cause(s) ERR1**** OC.Drive OC.Decel OC.Accel Over.C While at constant speed Over-current protection The inverter output was short-circuited, or the motor shaft is locked or has a heavy load. These conditions cause excessive current for the inverter, so the inverter output is turned off.
CONNECTING DIAGRAM Source type logic 200V class 200V-240V+10%, -15% 50/60Hz±5% 400V class 380V-480V+10%, -15% 50/60Hz±5% SJ700/SJ700B R(L1) S(L2) (T3)W T(L3) (+1)PD T(J51) R0 T0 Dynamic braking unit (BRD) (+)P RB - + FM monitor output (PWM) DC0-10V DC4-20mA(12bit) AM monitor output (Analog output) DC0-10V(10bit) R1 6 1 15 FM DC24V 11 AL1 RB AL2 P P P RB RB N Braking resistor(RB) ( ) Intelligent output terminals (5 terminals) CM2 SP O SN 10kΩ O2 OI AL1 RB AL2 P The alarm r
CONNECTING DIAGRAM Sink type logic 200V class 200V-240V+10%, -15% 50/60Hz±5% 400V class 380V-480V+10%, -15% 50/60Hz±5% SJ700/SJ700B R(L1) S(L2) (T3)W (+1)PD T(L3) T(J51) R0 T0 Dynamic braking unit (BRD) (+)P RB - + FM monitor output (PWM) DC0-10V DC4-20mA(12bit) AM monitor output (Analog output) DC0-10V(10bit) R1 6 Intelligent relay output contacts (default:alarm output) *1 1 15 FM 11 P P RB RB N Braking resistor(RB) ( Intelligent output terminals (5 terminals) CM2 SP O SN 10k
CONNECTING TO PLC Connection with Input Terminals 1.
WIRING and ACCESSORIES Power Supply Fuse 200V 400V R (L1) S (L2) T PD (+1) (L3) RB (T1) U (-)N (T2) V (T3) W Name SJ700B 110HFF 150HFF 185HFF 220HFF 300HFF 370HFF 450HFF 550HFF 750HFF 900HFF 1100HFF 1320HFF 1600HFF - 14 14 14 14 10 8 6 6 2 1 1 2/0 4/0 4/0 2/0X2 14 14 14 14 12 10 8 6 6 6 3 1 1 2/0 1/0X2 1/0X2 3/0X2 3/0X2 3/0X2 300X2 350X2 500X2 800X2 - - 2.1 2.1 2.1 2.1 5.3 8.4 13.3 13.3 33.6 42.4 42.4 67.4 107.2 107.2 67.4X2 2.1 2.1 2.1 2.1 3.3 5.3 8.4 13.3 13.3 13.3 26.7 42.4 42.
TORQUE CHARACTORISTIC SJ700 Series / Maximum Torque with Short - Time Rating V/f control (maximum torque boosting) 0.4 55kW 150 75 132kW 180 130 55 132kW 65Hz max. 150 130 55 132kW 0.4 3.7kW 5.5 22kW 30 45kW 60 55 45 0.3 46 60 65 Output frequency (Hz) 100 Output torque (%) 200 Output torque (%) Base frequency = 60Hz Sensorless vector control 60 55 45 0.3 6 120 109 0.4 3.7kW 5.
TORQUE CHARACTORISTIC Output torque (%) 100 95 92 Sensorless vector control V/f control 0.4 11kW 15 22kW 30 55kW 55 132kW 30 45kW 80 0.4 3.7kW 70 55 5.5 22kW 45 35 30 0.3 6 20 60 65 100 Output frequency (Hz) Sensorless vector control V/f control Output torque (%) 0.4 3.7kW Base frequency = 50Hz Base frequency = 60Hz SJ700/SJ700B Series / Torque Under Continous Operation 120 Output frequency (Hz) DERATING DATA SJ700 200V class Output current(Ratio to the rating:%) 0.4 7.
DIFFERENCE and COMPATIBILITY of SJ300 series and SJ700 series SJ300 series Items SJ700 series Copying the parameter settings You can copy the parameter settings from the SJ300 series into the SJ700 series. (You cannot copy the parameter settings from the SJ700 series to the SJ300 series because the SJ700 series has many new functions and additional parameters.) Parameter display mode. No display mode selection. (full display) Basic display mode/Data comparison function addition.
DIFFERENCE and COMPATIBILITY of L300P series and SJ700B series L300P series Items Copying the parameter settings No display mode selection. (full display) Basic display mode/Data comparison function addition. Note:basic display mode [factory setting])To display all parameters, specify "00" for "b037". Retry or trip parameter Instantaneous power failure/under-voltage/ overvoltage/overcurrent:It sets up by b001. Instantaneous power failure/under-voltage:It sets up by b001.
MEMO 32
FOR CORRECT OPERATION Application to Motors Application to general-purpose motors Operating frequency The overspeed endurance of a general-purpose motor is 120% of the rated speed for 2 minutes (JIS C4,004). For operation at higher than 60Hz, it is required to examine the allowable torque of the motor, useful life of bearings, noise, vibration, etc. In this case, be sure to consult the motor manufacturer as the maximum allowable rpm differs depending on the motor capacity, etc.
Installation location and operating environment Avoid installation in areas of high temperature, excessive humidity, or where moisture can easily collect, as well as areas that are dusty, subject to corrosive gasses, mist of liquid for grinding, or salt. Install the inverter away from direct sunlight in a well-ventilated room that is free of vibration. The inverter can be operated in the ambient temperature range from -10 to 50˚C.
Printed in Japan (T) SM-E268P 0712