User Guide

20
ENGLISH
ALARM RECORDING
This VCR can automatically record at one of three
speeds (03, 12 or 24) on ALARM command.
To program the ALARM function refer to page 17.
The remote/contact switch must be connected to the
VCR. See page 8.
To operate the ALARM recording in the stop mode:
follow the tape recording procedure, step 1, then
select “YES” of the ALARM READY menu in the
ALARM display.
MASTER SYSTEM RESET
Press the two reset buttons simultaneously to pro-
vide a MASTER SYSTEM RESET. Use to reset
abnormal displays and operations. The program-
mable features must be re-programmed.
PLAYBACK
1. Rewind the tape to the desired beginning point.
(Press the REWIND button, and observe the digi-
tal counter until the desired number appears.)
Press the stop button.
2. Press the REC/PLAY HOURS button until the
desired tape speed is observed on the tape speed
indicator.
3. Press the PLAY button to initiate forward play-
back.
To select reverse playback, press the PLAY but-
ton and then press the REVERSE PLAY button.
Forward playback resumes when the PLAY but-
ton is pressed.
Notes:
When the REVERSE PLAY button is pressed in
the forward playback mode to set the VCR to
the reverse playback mode, the first several
frame images may be distorted.
The VCR will automatically enter the STOP
mode if the reverse play is continued for
approx. 1 minute.
4. Press the STOP button to stop playback.
Notes:
The tape speed mode can be changed during
playback.
When a picture recorded in the 03 mode is played
back in the A12 or A24 mode, it includes noise. It
is recommended that you play back pictures
recorded in the 03 mode at modes higher than 24.
When the tape reaches the end, the unit auto-
matically rewinds to the beginning of the tape
and then goes to the STOP mode.
If the monitor display exhibits distortion in the
upper part of the picture, adjust the horizontal
hold control on the monitor.
Adjust the SLOW TRACKING control to minimize
noise when playing back at slow speed (24 hours)
or in the FIELD ADVANCE/REVERSE mode.
The playback picture is not stable and has some
noise at A12 or A24 mode. And in these modes
TRACKING control is not effective.
SHARPNESS CONTROL
When the SHARPNESS CONTROL button is pressed
during playback, then within 5 seconds press the
SOFT or HARD button to change picture quality to
soft or hard by 5 steps.
LCD display:
STILL PLAYBACK
When the STILL button is pressed during playback,
a still picture can be seen. To start again press STILL
or PLAY button and the VCR will continue playback.
Notes:
When still playback continues for more than 5
minutes, the AUTO-PROTECT circuit operates and
the VCR will enter the STOP mode automatically.
If the picture shakes up and down during still
playback, press the V.LOCK buttons.
V.LOCK ADJUST
If the picture shakes up and down during still play-
back, adjust the picture by the following procedure.
1. Play back a tape, recorded in the 03 mode, in the
still playback mode.
With some TVs, if the V.LOCK buttons are
pressed when playing a tape recorded in
modes other than 03, shaking of the still pic-
ture may not stop.
2. Press the V.LOCK buttons so the shaking of the
picture stops.
Note: Shaking of the picture may not be stopped
completely depending on the TV used.
PLAYBACK IN THE FIELD ADVANCE/REVERSE
MODES
When you press the FIELD ADVANCE or FIELD
REVERSE button during still playback mode, one
field at a time can be seen.
Operates only after STILL button has been pressed.
Notes:
An AUTO-PROTECT circuit automatically returns
the unit to the STOP mode if the STILL or PLAY
button is not pressed again or if FIELD ADVANCE
or FIELD REVERSE button is not pressed in any
five minute period.
When the FIELD REVERSE button is pressed in
the still playback mode to set the VCR to the field
reverse mode, the first several frame images may
be distorted.
SOFT
SOFT
21
HARD
1
HARD
20