Brochure

13
Code Function Name Setting Range
Setting During
Operation
(allowed or not)
Change During
Operation
(allowed or not)
Default
Setting
Multispeed
and Jogging frequency setting
A019 Multi-speed operation selection 00 (Binary mode) / 01 (Bit mode) × × 00
A020 Multi-speed 0 setting 0.00 / "start frequency" to "maximum frequency (1st)" [Hz] 0.00
A220 Multi-speed 0 setting, 2nd motor 0.00 / "start frequency" to "maximum frequency (2nd)" [Hz] 0.00
A021 A035
Multi-speed 1 15 setting 0.00 / start frequency” to “maximum frequency” [Hz] 0.00
A038 Jog frequency setting “start frequency” to 9.99 [Hz] 6.00
A039 Jog stop mode
00 (Free-run stop [invalid during run]) /
01 (Controlled deceleration [invalid during run]) /
02 (DC braking to stop [invalid during run]) /
03 (Free-run stop [valid during run])
04 (Controlled deceleration [valid during run])
05 (DC braking to stop [valid during run])
× 04
V/ f Characteristic
A041 Torque boost select
00 (manual torque boost) /
01 (automatic torque boost)
× × 00
A241 Torque boost select, 2nd motor × × 00
A042 Manual torque boost value 0.0 to 20.0 [%] 1.0
A242 Manual torque boost value, 2nd motor 0.0 to 20.0 [%] 1.0
A043 Manual torque boost frequency adjustment 0.0 to 50.0 [%] 5.0
A243 Manual torque boost frequency adjustment, 2nd motor 0.0 to 50.0 [%] 5.0
A044 V/ f characteristic curve selection 00 (VC) / 01 (VP) / 02 (free V / f) / 03 (SLV) × × 00
A244 V / f characteristic curve selection, 2nd motor 00 (VC) / 01 (VP) / 02 (free V / f) / 03 (SLV) × × 00
A045 V / f gain setting 20 to 100 [%] 100
A245 V / f gain setting, 2nd motor 20 to 100 [%] 100
A046 Voltage compensation gain for automatic torque boost 0 to 255 100
A246 Voltage compensation gain for automatic torque boost, 2nd motor 0 to 255 100
A047 Slip compensation gain for automatic torque boost 0 to 255 100
A247 Slip compensation gain for automatic torque boost, 2nd motor 0 to 255 100
DC braking
A051 DC braking enable 00 (disabled) / 01 (enabled) / 02 (output freq < [A052]) × 00
A052 DC braking frequency setting 0.00 to 60.00 [Hz] × 0.50
A053 DC braking wait time 0.0 to 5.0 [s] × 0.0
A054 DC braking force for deceleration 0 to 100 / 70 [%] (CT / VT) × 50
A055 DC braking time for deceleration 0.0 to 60.0 [s] × 0.5
A056 DC braking / edge or level detection for [DB] input 00 (edge operation) / 01 (level operation) × 01
A057 DC braking force at start 0 to 100 / 70 [%] (CT / VT) × 0
A058 DC braking time at start 0.0 to 60.0 [s] × 0.0
A059 Carrier frequency during DC braking 2.0 to 15.0 / 10.0 [kHz] (CT/ VT) × 5.0
Frequency upper / lower limit
and Jump frequency
A061 Frequency upper limit setting 0.00 / A062 to A004 [Hz] × 0.00
A261 Frequency upper limit setting, 2nd motor 0.00 / A262 to A204 [Hz] × 0.00
A062 Frequency lower limit setting 0.00 / b082 to A061 [Hz] × 0.00
A262 Frequency lower limit setting, 2nd motor 0.00 / b082 to A261 [Hz] × 0.00
A063 Jump (center) frequency setting 1 0.00 to 99.99 / 100.0 to 400.0 [Hz] × 0.00
A064 Jump (hysteresis) frequency width setting 1 0.00 to 10.00 [Hz] × 0.50
A065 Jump (center) frequency setting 2 0.00 to 99.99 / 100.0 to 400.0 [Hz] × 0.00
A066 Jump (hysteresis) frequency width setting 2 0.00 to 10.00 [Hz] × 0.50
A067 Jump (center) frequency setting 3 0.00 to 99.99 / 100.0 to 400.0 [Hz] × 0.00
A068 Jump (hysteresis) frequency width setting 3 0.00 to 10.00 [Hz] × 0.50
A069 Acceleration stop frequency setting 0.00 to 99.99 / 100.0 to 400.0 [Hz] ×
0.00
A070 Acceleration stop time setting 0.0 to 60.0 [s] × 0.0
PID control
A071 PID enable 00 (disabled) / 01 (enabled) / 02 (enabled inverted-data output) × 00
A072 PID proportional gain 0.00 to 25.00 1.00
A073 PID integral time constant 0.0 to 999.9 / 1000. to 3600. [s] 1.0
A074 PID derivative time constant 0.00 to 99.99 / 100.0 [s] 0.00
A075 PV scale conversion 0.01 to 99.99 × 1.00
A076 PV source setting
00 (input via OI) / 01 (input via O) / 02 (external communication) /
03 (pulse train frequency input) / 10 (operation result output)
× 00
A077 Reverse PID action 00 (OFF) / 01 (ON) × 00
A078 PID output limit 0.0 to 100.0 [%] × 0.0
A079 PID feed forward selection 00 (disabled) / 01 (O input) / 02 (OI input) × 00
AVR function
A081 AVR function select 00 (always on) / 01 (always off) / 02 (off during deceleration) × × 02
A281 AVR function select, 2nd motor 00 (always on) / 01 (always off) / 02 (off during deceleration) × × 02
A082 AVR voltage select
200 V class : 200 / 215 / 220 / 230 / 240 (V)
400 V class : 380 / 400 /415 / 440 / 460 / 480 (V)
× × 200/400
A282 AVR voltage select, 2nd motor
200 V class : 200 / 215 / 220 / 230 / 240 (V)
400 V class : 380 / 400 /415 / 440 / 460 / 480 (V)
× × 200/400
A083 AVR lter time constant 0.000 to 9.999 / 10.00 [s] × 0.300
A084 AVR deceleration gain 50 to 200 [%] × 100
Function List
[ = Allowed × = Not parmitted]