*1: The applicable motor refers to Hitachi standard 3-phase motor (4p). When using other motors, care must be taken to prevent the rated motor current (50/60Hz) from exceeding the rated output current of the inverter.
*2: The output voltage varies as the main supply voltage varies (except when using the AVR function). In any case, the output voltage cannot exceed the input power supply voltage.
Models WJ200- 001LF 002LF 004LF 007LF 015LF 022LF 037LF 055LF 075LF 110LF 150LF
Applicable motor size *
1
kW
VT 0.2 0.4 0.75 1.1 2.2 3.0 5.5 7.5 11 15 18.5
CT 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15
HP
VT 1/4 1/2 1 1.5 3 4 7.5 10 15 20 25
CT 1/8 1/4 1/2 1 2 3 5 7.5 10 15 20
Rated capacity (kVA)
200V
VT 0.4 0.6 1.2 2.0 3.3 4.1 6.7 10.3 13.8 19.3 23.9
CT 0.2 0.5 1.0 1.7 2.7 3.8 6.0 8.6 11.4 16.2 20.7
240V
VT 0.4 0.7 1.4 2.4 3.9 4.9 8.1 12.4 16.6 23.2 28.6
CT 0.3 0.6 1.2 2.0 3.3 4.5 7.2 10.3 13.7 19.5 24.9
Input
Rating
Rated input voltage (V) 3-phase: 200V-15% to 240V +10%, 50 / 60Hz ±5%
Rated input current (A)
VT 1.2 1.9 3.9 7.2 10.8 13.9 23.0 37.0 48.0 68.0 72.0
CT 1.0
1.6 3.3 6.0 9.0 12.7 20.5 30.8 39.6 57.1 62.6
Output
Rating
Rated output voltage (V) *
2
3-phase: 200 to 240V (proportional to input voltage)
Rated output current (A)
VT 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
CT 1.0 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Minimum value of resistor (Ω) 100 100 100 50 50 35 35 20 17 17 10
Cooling method Self-cooling Force ventilation
Weight
kg 1.0 1.0 1.1 1.2 1.6 1.8 2.0 3.3 3.4 5.1 7.4
lb 2.2 2.2 2.4 2.6 3.5 4.0 4.4 7.3 7.5 11.2 16.3
Models WJ200- 001SF 002SF 004SF 007SF 015SF 022SF
Applicable motor size *
1
kW
VT 0.2 0.4 0.55 1.1 2.2 3.0
CT 0.1 0.2 0.4 0.75 1.5 2.2
HP
VT 1/4 1/2 3/4 1.5 3 4
CT 1/8 1/4 1/2 1 2 3
Rated capacity (kVA)
200V
VT 0.4 0.6 1.2 2.0 3.3 4.1
CT 0.2 0.5 1.0 1.7 2.7 3.8
240V
VT 0.4 0.7 1.4 2.4 3.9 4.9
CT 0.3 0.6 1.2 2.0 3.3 4.5
Input
Rating
Rated input voltage (V) 1-phase: 200V-15% to 240V +10%, 50 / 60Hz ±5%
Rated input current (A)
VT 2.0 3.6 7.3 13.8 20.2 24.0
CT 1.3 3.0 6.3 11.5 16.8 22.0
Output
Rating
Rated output voltage (V) *
2
3-phase: 200 to 240V (proportional to input voltage)
Rated output current (A)
VT 1.2 1.9 3.5 6.0 9.6 12.0
CT 1.0 1.6 3.0 5.0 8.0 11.0
Minimum value of resistor (Ω) 100 100 100 50 50 35
Cooling method Self-cooling Force ventilation
Weight
kg 1.0 1.0 1.1 1.6 1.8 1.8
lb 2.2 2.2 2.4 3.5 4.0 4.0
Models WJ200- 004HF 007HF 015HF 022HF 030HF 040HF 055HF 075HF 110HF 150HF
Applicable motor size *
1
kW
VT 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
CT 0.4 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15
HP
VT 1 2 3 4 5 7.5 10 15 20 25
CT 1/2 1 2 3 4 5 7.5 10 15 20
Rated capacity (kVA)
200V
VT 1.3 2.6 3.5 4.5 5.7 7.3 11.5 15.1 20.4 25.0
CT 1.1 2.2 3.1 3.6 4.7 6.0 9.7 11.8 15.7 20.4
240V
VT 1.7 3.4 4.4 5.7 7.3 9.2 14.5 19.1 25.7 31.5
CT 1.4 2.8 3.9 4.5 5.9 7.6 12.3 14.9 19.9 25.7
Input
Rating
Rated input voltage (V) 3-phase: 380V-15% to 480V +10%, 50 / 60Hz ±5%
Rated input current (A)
VT 2.1 4.3 5.9 8.1 9.4 13.3 20.0 24.0 38.0 44.0
CT 1.8 3.6 5.2 6.5 7.7 11.0 16.9 18.8 29.4 35.9
Output
Rating
Rated output voltage (V) *
2
3-phase: 380 to 480V (proportional to input voltage)
Rated output current (A)
VT 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
CT 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Minimum value of resistor (Ω) 180 180 180 100 100 100 70 70 70 35
Cooling method Self-cooling Force ventilation
Weight
kg 1.5 1.6 1.8 1.9 1.9 2.1 3.5 3.5 4.7 5.2
lb 3.3 3.5 4.0 4.2 4.2 4.6 7.7 7.7 10.4 11.5
3-phase 200V class
1-phase 200V class
3-phase 400V class
Standard Specications
Models WJ200- 004MF 007MF
Applicable motor size *
1
kW 0.4 0.75
HP 1/2 1
Rated capacity (kVA)
100V 1.0 1.7
120V 1.2 2.0
Input
Rating
Rated input voltage (V)
1-phase:
100V-10% to 120V +10%,
50/ 60Hz ±5%
Rated input current (A)
14 24
Output
Rating
Rated output voltage (V) *
2
3-phase:
200 to 240V
(proportional to input voltage)
Rated output current (A)
3.5 5.0
Minimum value of resistor (Ω) 100 50
Cooling method Self-cooling
Weight
kg 1.1 1.6
lb 2.4 3.5
1-phase 100V class (only with CT)