Operation Manual

English
9
SPECIFICATIONS
POWER TOOL
Model WH14DBAL2 WH18DBAL2
Voltage 14.4 V 18 V
High mode 0 – 2800 min
–1
0 – 2900 min
–1
No-load Medium mode 0 – 2200 min
–1
0 – 2200 min
–1
speed
Low 2 mode 0 – 1500 min
–1
0 – 1500 min
–1
Low 1 mode 0 – 900 min
–1
0 – 900 min
–1
Capacity
Ordinary bolt M5 – M14
High tension bolt M5 – M12
Tightening torque (Maximum) 160 N·m 160 N·m
Rechargeable battery
BSL1430: Li-ion BSL1440: Li-ion BSL1830: Li-ion BSL1840: Li-ion
14.4 V (3.0 Ah 8 cells) 14.4 V (4.0 Ah 8 cells)
18 V (3.0 Ah 10 cells) 18 V (4.0 Ah 10 cells)
Weight 1.4 kg 1.5 kg
Model WR14DBAL2 WR18DBAL2
Voltage 14.4 V 18 V
High mode 0 – 2800 min
–1
0 – 2900 min
–1
No-load Medium mode 0 – 2200 min
–1
0 – 2200 min
–1
speed
Low 2 mode 0 – 1500 min
–1
0 – 1500 min
–1
Low 1 mode 0 – 900 min
–1
0 – 900 min
–1
Capacity
Ordinary bolt M6 – M16
High tension bolt M6 – M12
Tightening torque (Maximum) 165 N·m 165 N·m
Rechargeable battery
BSL1430: Li-ion BSL1440: Li-ion BSL1830: Li-ion BSL1840: Li-ion
14.4 V (3.0 Ah 8 cells) 14.4 V (4.0 Ah 8 cells)
18 V (3.0 Ah 10 cells) 18 V (4.0 Ah 10 cells)
Weight 1.4 kg 1.5 kg
PRECAUTIONS REGARDING THE DUST-
RESISTANCE AND WATER-PROOFING FUNCTIONS
This product conforms to IP56 protection class ratings (dust-resistance and water-proofing) for electrical equipment as
stipulated by the international IEC regulations. (Only the main unit conforms to the IP56 protection class ratings when
equipped with a battery.)
[Descriptions of IP Codes]
IP56
Protection rating for water penetration
Must be no adverse effects on the equipment when sprayed with powerful jets of water from all directions
(water-proofed).
(100L of water per minute sprayed for approximately three minutes from a distance of approximately three
meters with the use of a spray nozzle with a diameter of 12.5mm.)
Protection rating for external assault by solid objects
Dust that may cause adverse effects on the equipment must not be able to enter (dust-resistance).
(The equipment to be left non-operable in a test chamber in which particles of talcum powder with a
diameter of less than 75
are floating in the air with the use of an agitation pump at a rate of 2kg per cubic
meter for eight hours.)
The equipment has been designed to withstand the effects of dust and water, but there is no guarantee that it will not
malfunction. Do not use or leave the equipment in locations where it is subject to excessive amounts of dust, or in
locations where it is submerged in water or subject to rainwater.
01Eng_WH14DBAL2_WE 7/10/12, 16:149