RDX2 Pro Manual
19
Note
Once the battery is fully discharged, the screen will read
“END: CUTOFF-VOL” and the charger will emit an audible “ring”
sound. It will also display the Time Elapsed, End Voltage and
Capacity in mAh that was removed.
You can press the STOP button at any time during the
discharging process to stop discharging.
A
A
A
A
[TIME: 01:04:04]
NiMH RE-PEAK
NiMH RE-PEAK
NiMH 1.3A 6.42V
1
1
RPC 004:04 00686
NiMH/NiCd Battery Program
NiMH/NiCd Re-Peak Mode:
Applicable to NiMH and NiCd batteries only, in Re-Peak Mode,
the charger can top o the battery once, twice, or three times
in a row automatically. This process is good for con rming
that the battery is fully charged after it had been previously
charged and sitting for a while. A ve-minute cool-down
delay occurs after each Re-Peak Charge.
NOTE: IN RE-PEAK MODE, THE RDX2 PRO
USES THE CHARGE AMPERAGE AND VOLTAGE
SETTINGS ENTERED IN CHARGE MODE.
After selecting the correct battery type, SCROLL to select the
‘RE-PEAK’ mode. Press the Jog Dial ENTER and the Re-Peak
cycle number 1 begins to ash on the screen. SCROLL to adjust
the cycle count between 1 and 3.
Press and hold the START button for 3 seconds to start the
Re-Peak process.
Once the Re-Peak process has begun, the charger will display
the following real-time information: battery type, charging
current, battery voltage, RPC (Re-Peak Charge mode), elapsed
time and charged capacity.
Once the Re-Peak process is completed, the screen will read
“END: RE-PEAK” and the charger will emit an audible “ring”
sound.
It will also display the nal voltage, and charged capacity.
A
BATTERY CHECK
.............
A
A
[END: CUTOFF-VOL]
[END: RE-PEAK]
5.00V 01980mAh
5.00V 01980mAh
6.75V 00980mAh
A
[TIME:00:05:32]
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
NiMH RE-PEAK
A
A
A
A
*FLASHING
6.75V 00980mAh