RDX2 Pro Manual
28
System Settings
The RDX2 Pro will be operated with the default value for the essential user settings when it is powered on for
the rst time. The screen displays the following information in sequence and the user can change the param-
eter value of each screen. To change a parameter value in the system program, press START/ENTER to make
it blink then change the value with the dial button. The value will be stored by pressing START/ENTER once.
130W rated power for both Channel A and
Channel B. Power supply function is available
under AC/DC mode.
When you start a charge process, the integral
safety timer automatically starts running at the
same time. This is programmed to prevent over-
charge the battery if it proves to be faulty, or if the
termination circuit cannot detect the battery full.
The value for the safety timer should be generous
enough to allow a full charge of the battery.
This program sets the maximum charge capacity
that will be supplied to the battery during charge.
If the delta peak voltage is not detected nor the
safety timer expired for any reason, this feature
will automatically stop the process at the selected
capacity value.
You can choose the temperature displayed by
Celsius or Fahrenheit as you like.
A rest time allowing the battery to cool down
between charging/discharging cycle.
U: 5.0-25.0V
I: 0.1-14.0A
OFF/ON
(1-720 Min)
OFF/ON
(100-50000 mAh)
Celsius
Fahrenheit
1-60 Min
ITEM SELECTION DESCRIPTION
A
POWER SET
U=0.0V I=0.0A
A
SAFETY TIMER
ON 120 MIN
A
CAPACITY CUT-OFF
ON 5000mAh
A
TEMPERATURE UNIT
CELSIUS
A
REST TIME
CHG > DCHG 10 Min