RDX2 Pro Manual

5
Warning
A battery that is non-rechargeable (these pose an explosion hazard)
A faulty or damaged battery
Batteries installed in a device or which are electrically linked to other components
Batteries that are not expressly stated by the manufacturer to be suitable for the currents
the charger delivers during the charge process
PLEASE BEAR IN MIND THE FOLLOWING POINTS BEFORE YOU COMMENCE CHARGING:
Did you select the appropriate program suitable for the type of battery you are charging?
Did you set up the adequate current for charging or discharging?
Have you checked the battery voltage? Lithium battery packs can be wired in parallel and in
series, i.e. a 2-cell pack can be 3.7V (in parallel) or 7.4V (in series).
Have you checked that all connections are  rm and secure?
Make sure there are no intermittent contacts at any point in the circuit.
LiPo LiPo HV LiIon LiFe NiCd NiMH Pb
Nominal
Volt age
3.7V/cell 3.8V/cell 3.6V/cell 3.3V/cell 1.2V/cell 1.2V/cell 2.0V/cell
Max. Charge
Volt age
4.2V/cell 4.35V/cell 4.1V/cell 3.6V/cell 1.5V/cell 1.5V/cell 2.46V/cell
Storage
Volt age
3.8V/cell 3.85V/cell 3.7V/cell 3.3V/cell n/a n/a n/a
Allowable Fast
Charge
≤ 1C ≤ 1C ≤ 1C ≤ 4C ≤ 1-2C ≤ 1-2C ≤ 0.4C
Min. Discharge
Volt age
3.0-3.3V/cell 3.1-3.4V/cell 2.9-3.2V/cell 2.6-2.9V/cell 0.1-1.1V/cell 0.1-1.1V/cell 1.8V/cell
Standard Battery Parameters
WHEN ADJUSTING YOUR RDX2 PRO CHARGING PARAMETERS, BE SURE YOU
SELECT THE PROPER BATTERY TYPE AND CELL VOLTAGE FOR THE TYPE OF CELL
YOU ARE CHARGING. CHARGING BATTERIES WITH THE WRONG SETTINGS MAY
CAUSE THE CELLS TO BURST, CATCH FIRE OR EXPLODE.
Warnings and Safety Notes