CAUTION – Program the Fail Safe point
after setting the end and center points,
otherwise it will change when you make
those adjustments.
WARNING
WARNING
To set the Fail Safe point rst click on the Fail Safe
under Program section.
7. Fail Safe Position
By choosing to use the Fail Safe function you will
need to set a preprogrammed travel point that the
servo will travel to in the event the servo loses signal
from the receiver.
Next move your servo to the desired position by
using the “Manual” positioning adjustments.
Once you have your desired Fail Safe position, click
on the “FS-Position” button in the Fail Safe Test
section to set the fail safe position. Once it is set, click
the button again to exit the Fail Safe setup.
NOTE – Remember to “Write All” of
your settings to your servo before closing
the DPC-11 software and disconnecting
your servo. Failure to do so will result in
lost programming data.
WARNING
WARNING
HSB-9XXX Servo Programming cont.