1.2 DIP Switch Settings
.
1.2.1 Mini Speed Dome Settings
DIP Switch Location of Mini Analog Speed Dome
DIP Switch
Figure 1-2 DIP Switch of Mini Analog Speed Dome
Setting DIP Switch
1 75 6432 8 9 10
ON DIP
1 2
ON
Figure 1-3 Enlarged View of DIP Switch
Table 1-2 Switch Functions
Switch No.
Function
1 to 5 (SW1)
Set the address for the speed dome
6, 7 (SW1)
Set the baudrate for the speed dome
8, 9 (SW1)
Set the protocol for the speed dome
10 (SW1)
Set the TVI mode for the speed dome
1,2 (SW2)
Set the terminal resistor for the speed dome
The DIP switch is designed according to binary system. When the switch is ON, it stands for the
number 1. When the switch is OFF, it stands for the number 0.
Example:
The SW1 switches from No. 1 to 5 are used to set the speed dome address. No. 1 is the lowest digit
and No. 5 is the highest. Turning on all these 5 switches stands for the binary number 11111.
Converting the 11111 to a decimal number is 31. So the speed dome address will be 31.