Product Info

Smart Cabinet Lock version1.0
D2-2F, MOJU INDUSTRIAL PARK, #199, XIQU AVENUE, HI-TECH ZONE WEST, CHENGDU, SICHUAN, CHINA.
13
/
25
New Version
Front of PCB
Back of PCB
If the P1 socket is connected to the DC power supply of the cabinet, the switch
K1 must be placed on the upper part, where is at the position of 8-50V, please check
the picture” Back of PCB”. At this time, the DC power supply of the cabinet will be
preferentially used, and it will automatically switch to the battery power supply when
the DC power supply of the cabinet is cut off. If the DC power supply of the cabinet is
not connected to the P1 socket, it is better to put the switch K1 at the bottom part,
where is at the position of character CR123A position, then the battery has greater
utilization.
4. Installation
After the whole installation process is completed, the test should be carried out.
During the test, the cabinet door should be opened for preliminary test. After the test
socket
function
remark
P1
Connect with DC
power in cabinet
DC 8V 50V. Note: left is
positive electrodeand right is Negative
electrode , according to marks onPCB.
P2
Connect with the
cabinet lock
From left to right are power ground, power
positive and door switch