Datasheet

ISO9001
ISO/TS16949
ISO14001 Approved
HRS4-68
COIL DATA
Ambient Temperature: 23
Model
Nominal Voltage
VDC
Coil Resistance
Ω+/-10%
Operate Voltage
≤VDC
Release Voltage
≥VDC
Coil Power
mW
450
HRS4-S-DC3V
HRS4-S-DC5V
HRS4-S-DC6V
HRS4-S-DC9V
HRS4-S-DC12V
HRS4-S-DC24V
HRS4-S-DC48V
HRS4H-S-DC3V
HRS4H-S-DC5V
HRS4H-S-DC6V
HRS4H-S-DC9V
HRS4H-S-DC12V
HRS4H-S-DC24V
HRS4H-S-DC48V
3
5
6
9
12
24
48
3
5
6
9
12
24
48
20
55
80
180
320
1280
5120
25
70
100
225
400
1600
6400
2.1
3.5
4.2
6.3
8.4
16.8
33.6
2.1
3.5
4.2
6.3
8.4
16.8
33.6
0.3
0.5
0.6
0.9
1.2
2.4
4.8
0.3
0.5
0.6
0.9
1.2
2.4
4.8
360
HRS4
POWER RELAY
3 - 48VDC
NO/NC: 10A/6A 250VAC
Ambient Temperature: 105
Ambient Temperature: 105
10A 120VAC/28VDC
N O : 1 0 A ( 2 ) A 2 5 0 V A C
NC: 6(1)A 250VAC
15A 125VAC
3 - 48VDC
Class F Insulation
3 - 48VDC
3 - 48VDC
Ambient Temperature: 65
TV-5 125VAC
Class F Insulation
Ambient Temperature: 85
10A 277VAC
Ambient Temperature: 105
Class F Insulation
SAFETY APPROVAL
Coil
Voltage
Remarks
NLDX Category
(N.O.Contact side)
1/2HP 120VAC
1/2HP 240VAC
3 - 48VDC
10A 120VAC/24VDC
TUV 50116136
TUV50116136 (EN 60730-1)
UL E164730
UL E322395
CSA 1063016 (LR 109368)
0.36W/0.45W
0.36W/0.45W
0.36W/0.45W
0.36W/0.45W
0.36W/0.45W
Power
Consumption
A/B/C
A
A/C
A/C
A/C
Contact
Form
File Number Contact Rating
Specications subject to change without notice