User's Guide
Table Of Contents
- 1 Introduction
- 2 Installing Arcadia Central Station
- 2.1 Front Panel Connectors, Controls and Indicators
- 2.2 Intercom Touchscreens
- 2.3 Rear Panel Connectors and Indicators
- 2.4 System Powering
- 2.5 Clear-Com Ethernet Cable Recommendations
- 2.6 Stage Announce and Program Feed
- 2.7 Set the Arcadia Central Station IP address
- 2.8 Save and Restore System Configuration
- 2.9 Reset to Default
- 2.10 Example Applications
- 3 Connecting to other systems
- 4 Network Setup
- 5 Core Configuration Manager (CCM) walkthrough
- 6 CCM configuration
- 6.1 Setting up the Arcadia Central Station
- 6.2 Adding IP Transceivers (FS Edge, FS II 1.9, 2.4)
- 6.3 Registering beltpacks
- 6.4 Viewing and adding Channels
- 6.5 Viewing and Adding Members to Groups
- 6.6 Channels or Groups?
- 6.7 Creating and Editing Roles
- 6.8 Set up GPIOs and Logic Events
- 6.9 Monitoring Your System from the CCM
- 7 Security
- 8 Configuring from the Front Panel
- 9 Spare parts
- 10 Terminology/glossary
- 11 Front Panel Menu Reference Tables
- 12 Specifications
- 13 Pinouts
- 14 Regulatory compliance
User Guide | Arcadia Central Station
13.3 4-wire pinouts (connector E)
Pin To panel To matrix
Pin 1 RS-422 input + (into matrix) RS-422 output + (from panel)
Pin 2 RS-422 input – (into matrix) RS-422 output - (from panel)
Pin 3 Audio input + (into matrix) Audio output + (from panel)
Pin 4 Audio output + (from matrix) Audio input + (into panel)
Pin 5 Audio output – (from matrix) Audio input – (into panel)
Pin 6 Audio input – (into matrix) Audio output – (from panel)
Pin 7 RS-422 output + (from matrix) RS-422 input + (into panel)
Pin 8 RS-422 output – (from matrix) RS-422 input – (into panel)
13.4 DECT Sync (connector F)
Pin Sync In Sync Out
Pin 1 DECTSYNC + DECTSYNC +
Pin 2 DECTSYNC - DECTSYNC -
Pin 3 8 KHZ+ 8 KHZ+
Pin 6 8 KHZ- 8 KHZ-
Caution: Shielded Cable Requirement
Shielded Cable is required for ALL FreeSpeak eGPIO Port connectivity. Shielded Cable must
be used to assure compliance with domestic and international emissions standards.
Customers, Installers and or qualified Personnel failing to use shielded cables may cause radio
interference in which case the user may be required to take adequate measures.
Page 101