User's Guide
Table Of Contents
- 1 Introduction
- 2 Installing Arcadia Central Station
- 2.1 Front Panel Connectors, Controls and Indicators
- 2.2 Intercom Touchscreens
- 2.3 Rear Panel Connectors and Indicators
- 2.4 System Powering
- 2.5 Clear-Com Ethernet Cable Recommendations
- 2.6 Stage Announce and Program Feed
- 2.7 Set the Arcadia Central Station IP address
- 2.8 Save and Restore System Configuration
- 2.9 Reset to Default
- 2.10 Example Applications
- 3 Connecting to other systems
- 4 Network Setup
- 5 Core Configuration Manager (CCM) walkthrough
- 6 CCM configuration
- 6.1 Setting up the Arcadia Central Station
- 6.2 Adding IP Transceivers (FS Edge, FS II 1.9, 2.4)
- 6.3 Registering beltpacks
- 6.4 Viewing and adding Channels
- 6.5 Viewing and Adding Members to Groups
- 6.6 Channels or Groups?
- 6.7 Creating and Editing Roles
- 6.8 Set up GPIOs and Logic Events
- 6.9 Monitoring Your System from the CCM
- 7 Security
- 8 Configuring from the Front Panel
- 9 Spare parts
- 10 Terminology/glossary
- 11 Front Panel Menu Reference Tables
- 12 Specifications
- 13 Pinouts
- 14 Regulatory compliance
User Guide | Arcadia Central Station
12 Specifications
12.1 Arcadia Arcadia Central Station Not yet done!
Specification Value
Arcadia Central
Station to beltpack
frequency response
l FreeSpeak II beltpacks: 100 - 7.1 kHz
l FreeSpeak Edge beltpacks: 12 kHz
Number of FS II
beltpacks per Arcadia
Central Station
Up to 16 beltpacks in total, made up of either FreeSpeak II or
FreeSpeak Edge beltpacks
Number of
transceivers
supported by Arcadia
Central Station
16 in total
l 6 IP transceivers (FreeSpeak II or FreeSpeak Edge)
l E1 transceivers, 2 connected directly to the Arcadia Central
Station, 10 via a splitter
Number of transceiver
ports
l E1 connections: 2 x RJ45 & 2 x Fiber (2 active at any time)
l IP transceiver connections 4 x LAN ports (configurable, default
= LAN 1)
Programming port 4 x LAN
GPIO port
2 x DB 9 connectors each hosting:
l 2 x relay outputs, normally open and normally closed wiring
l 1 x GPI
Partyline: A,B,C,D
l XLR-3F, ON/OFF termination control.
l Power ON/OFF (A/B, C/D paired)
l RTS or Clear-Com
4 -wire 8 X RJ45
Program input and
Stage Announce
output
A split cable is issued with the Arcadia Central Station for connection
to 4-wire port 8.
l XLR-3F, transformer isolated, line-level input, independent
Program Input level control via rotary encoder
Page 96