GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML-126423 HGFD45 FORM 35614 (February 2004) HGF35F ML-135536 HGF45F ML-135537 HGF65F ML-135538 HGF85F ML-135539 HGD35F ML-126953 HGD45F ML-126956 HGD65F ML-126959 HGD85F ML-126962 HGC35F ML-126954 HGC45F ML-126957 HGC65F ML-126960 HGC85F ML-1
– 26 –
Timers through :
1. Press
and enter the program mode. PROGRAM is displayed in the window.
2. Press
. The LED's on timers through are lit and SELECT PRODUCT is displayed
in the window.
3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the
window.
4. Enter the desired time using keys
through . The time is displayed in the window. After
entering the time, press
; SELECT PRODUCT is displayed in the window and the LED's on
timers
through are lit.
5. Repeat steps 3 and 4 to program the remaining timers or press
to exit the program
completely.
Advanced Time Features
Each timer has additional timing functions that can be programmed to fit your particular operation.
• DUTY TIME - Notifies the operator during a fry cycle to perform a particular task (shake a
basket, flip a product, etc.). When the remaining cook time is the same as the Duty Time, a
beeper sounds and DUTY # displays in the window. Press the flashing timer number to silence
the beeper. The beeper cancels after 5 seconds if not silenced.
• HOLD TIME - Starts after the initial timer beeper is silenced; HD# XX:XX is displayed in the
window. After timing out, a beeper sounds. Press the flashing timer number to silence the
beeper. The beeper cancels after 5 seconds if not silenced.
• COMPENSATED TIME - Automatically adjusts the time for variations in load sizes.
• STRAIGHT TIME - Does not adjust time for variations; used for regular timing operations.