GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER Instructions Manual MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML-126423 HGFD45 FORM 35614 (February 2004) HGF35F ML-135536 HGF45F ML-135537 HGF65F ML-135538 HGF85F ML-135539 HGD35F ML-126953 HGD45F ML-126956 HGD65F ML-126959 HGD85F ML-126962 HGC35F ML-126954 HGC45F ML-126957 HGC65F ML-126960 HGC85F ML-1

– 35 –
TROUBLESHOOTING GUIDE
SYMPTOM
No power when switch is
turned on.
Fryer will not heat.
Fryer continues to heat.
Fryer heats, but will not reach
desired temperature.
Fryer stops heating during
operation.
POSSIBLE CAUSES / SOLUTIONS
Tripped breaker; fuse blown / Verify fryer is plugged in and outlet
has power.
Problem with power switch / Call service.
Gas supply not on or partially on / Verify gas supply valve is full
on / Check hose connection (if applicable).
Verify power is on.
Gas valve in fryer not on / Verify gas valve is on in fryer / Verify
pilot comes on.
Problem with high limit / Call service.
Problem with electrical system / Turn off gas supply and call
service.
Combination valve is stuck in open position / Turn off gas supply
and call service.
Problem with electrical system / Call service.
Gas supply pressure inadequate / Call service.
Tripped breaker, fuse blown / Verify fryer is plugged in and check
circuit breakers and fuse(s).
Check gas supply. Verify pilot is on.
Shortening is too hot, high limit switch is open / Call service.