8.3 Boiler *
The optional boiler holds approx. 14 litres of
water. It uses gas to heat the water or, depen-
ding on the model, there is also an option to heat
it electrically using an integrated heating rod. It
replaces the standard Truma therme.
Before each journey, make sure the
boiler has been switched off and then
attach the chimney cap.
Before operating the boiler you must
remove the chimney cap.
Empty the boiler if there is a danger of
frost.
Never operate the boiler if it is empty.
Should you operate the cold water
system without the boiler, the boiler
will also be lled with water. To avoid
damage due to frost, empty the con-
tents even if the boiler has not been
used.
Filling the boiler
Shut the outlet valve on the cold water intake
pipe. Set the lever in a horizontal position.
Switch on the energy supply by pressing the
main switch on the control panel.
Open at least one faucet and leave it open
until the boiler has been lled by displacing
the air and the water ows.
Shut the faucet.
Emptying the boiler
Use the control panel to switch off the energy
supply.
Open the faucets in the kitchen and the ba-
throom.
Open the outlet valve on the boiler. Set the
lever in a vertical position.
Empty the water directly outside.