Operation Manual

10. Built-in devices
96
A
B
C
D E F G H I
J
K
Idle position
A. Clock. The clock shows the date and time (when activated).
B. *Outside temperature. The outside temperature is displayed.
C. Inside temperature. The inside temperature is displayed.
D. Circulation pump. This icon is displayed when the circulation
pump is in operation.
E. Starting the heating system automatically. This icon is displa-
yed when this function has been activated.
F. Daytime automatic system. This icon is displayed when this
function is activated.
G. *Liquid gas bottle full/empty. This icon is displayed when the
sensor on the gas regulator of the bottle is connected and has
been activated. Is a de-icer* has been installed, the icons will be
displayed for the set mode together with the bottle icon.
H. Nighttime automatic system. This icon is displayed when this
function is activated.
I. 230 volts. This icon is displayed when a voltage of 230 V is
applied to the heating system.
J. On/O button. Main switch for the heating system.
K. MENU key. Key for the settings menu.
The functions marked (
*
) are accessories. They have not been
installed in every vehicle.
Settings menu
Start the settings menu by pressing the MENU key. The backlight
goes on and those functions that can be set will be displayed. The
control unit will switch to the idle position after 30 seconds if the
screen is not operated.
Setting the desired temperature
The temperature can be set from +5 °C to +30 °C in steps of
0.5 °C.
1. The temperature shown is the temperature presently set.
2. Raise the temperature by pressing "+". Lower the temperature by
pressing "–".
3. The settings are now nished and the heating will run until the set
temperature has been reached.
It is not possible to set any temperature if the daytime
or nighttime automatic system is in operation. The plus
and minus icons are then greyed out.
Basic menu
Settings menu