Operation Manual

60
7. Installation of electrical devices
Soft key menu bar C
This is used to access the individual menus of the components.
Soft keys
The “soft keys” are used to carry out the commands displayed
inthelowermenubar(C).Forexample,theyenableaccessto
submenus, increase or reduce the values shown, or represent the
Returnbutton(“Back”function).
Control knob
Like the “soft keys”, the control knob enables easy navigation bet-
ween the individual menus. Turn the know to select the correspon-
ding menu item or display value shown to the left, or to increase or
reducevalues.Presstheknobtojumptosubmenusorconrma
value that has been changed.
Wassertank
automatic
tank
control
Wassertank
automatic
tank
control
Fresh water tank
Thelling level of the freshwater tankcan be reado here.The
alarmcanbeactivated(green)abovetheleftsoftkey(On/Oicon).
Ifthealarmhasbeenactivated,abeepwillgoowhenthetankis
beinglled.Thesebeepswillbesentatincreasinglyshorterinter-
valswhilethe tankislling up.The llinglevelof thefreshwater
tank will be automatically updated on the control panel every few
seconds.
Exitthismenuby usingthe“Back”function; otherwise,afterone
hour, it will automatically switch back to the main menu on the con-
trol panel.
Alarm
Battery management*
Thecurrentstatusoftheauxiliarybatteryisdisplayedinthebattery
menu(self-sucientpackage).Thechargingstatusisshowninthe
batteryicon;theexampleshowsafullychargedbattery.
“U” indicates the current charging voltage, “I” the current charging
current and the remaining time until the battery is discharged is dis-
played in hours. The value “T” indicates the temperature of the bat-
tery;thismustnotexceed50°C.Awarningmessagewillbesentif
thetemperatureexceeds50°Candthebatterywillbeshowninred
in the main menu on the control panel. If the battery is overheated,
it cannot be charged. Should this warning occur repeatedly, the
camper must be taken to an authorised specialist.
If the icons for the “Charger” appear, the camper is connected to a
230Vmainsconnectionandthechargecontrollerwasrecognised:
thebatterywillbecharged.Ifthecamperisconnectedtoa230V
mains connection and the icons for the Charger do not appear, the
battery will be charged using a characteristic.
The value “R” shows the calibration check. If “1” is output, the sen-
sorwillbecalibrated(targetstate).If“0”isoutput,themeasured
values may deviate slightly and the sensor should be recalibrated.
Batterie-
management
U : 12,3 V
I : 5,3 A
: 6,5 h
T : 0,0 °C
R : 0
Charger
GEL060 Ah
Batterie-
management
U : 12,3 V
I : 5,3 A
: 6,5 h
T : 0,0 °C
R : 0
Charger
GEL060 Ah
Battery charger
Batterie-
management
U : 12,3 V
I : 5,3 A
: 6,5 h
T : 0,0 °C
R : 0
Charger
GEL060 Ah