Operation Manual

70
7. Installation of electrical devices
To set up an electric connection
• Pulloutthe13-poleplugthatconnectstothebasevehicle.
• Switchotheautomaticcircuitbreaker
l
by pressing the
rocker button down
m
.
• TakeholdofthebottomofthecoverapoftheCEEexternal
socket
j
and pull it up.
• Completelyunwindtheconnectorcable.
• OpenthecapoftheCEEconnectorplugbypullingitupina
90°angle.
• Inserttheplug
k
until it locks into place.
•
Switch the automatic circuit breaker
l
back on.
Automatic circuit breaker with FI ('fast interrupt')
switch
2
1
Connected 230V feeder plug
4
3
To disconnect the electric connection
• Switchotheautomaticcircuitbreaker
l
by pressing the
rocker button down
m
.
• RemovetheCEEconnectorplug
k
.
• Pressthecoverap
j
down until it clicks into place.
Rules for the mains connection
• Useonlya3x2.5mm²cablewithamaximumlengthof25m,a
CEE connector plug and connector to connect the camper to an
external230Vmains.
• The230Vmainsconnectioninthecaravanhasbeendesigned
foratotalpowerconsumptionof2300W.Ifadditionaldevices
requiring electricity are connected, such as a water heater, etc.,
youmustensurethatthiselectricpowervalueisnotexceeded,
taking other electrical equipment in use, such as the refrigera-
tor, therme, etc., into account.
When obtaining electricity via a cable drum, this
must be completely unwound, as otherwise induc-
tion may cause the cable to heat up, which could
lead to burning (provided there is no protection
againstoverheating).
Protecting the 230V system
The230Vsystemisprotectedbyatwo-pole13Aautomaticcir-
cuit breaker
l
,whichislocatedintheclothescupboard(460HL
ONTOURintheseatingarrangement).(Exceptionstothisinclude
special installations, such as ultraheat, hot-water heating, etc..
In this case, an additional two-pole 16 A circuit breaker has been
installed.)Iftherearetwoautomaticcircuitbreakers,bothmustbe
switched on.
Only plugs and cords that comply with CEE stan-
dards may be used.