Operation Manual

10. Built-in devices
91
Open the valve on the gas bottle and the gas shuto valve on
the gas pipe.
Turn the operation handle
j
to the thermo-stat position 1-10.
Press the operation handle
j
down until it locks. The ignition
is automatic from this position, until the ame burns. The igni-
tion spark is audible. The control light on the automatic ignitor
blinks during ignition.
Hold the operation handle in for up to 10 seconds, so that the
ignition fuse kicks in.
If the gas line is lled with air, it can take up to a minute until the
gas is ready to burn. Hold the operation lever
j
in during this
period, until the ame burns.
1
To operate
Due to its design, the radiator cover gets hot when the
heating is on. The operator is responsible for exercising
due diligence so that third parties (especially small
children) are not hurt.
Should there be any diculty, please wait at least 3
minutes before re-attempting ignition; otherwise, there is
a danger of explosion.
If the ame goes out again, it will immediately be re-ignited
during the closing time of the safety pilot (approx. 30 seconds).
If no ame is ignited, the automatic ignitor will continue to work
until the operation handle
j
is switched to “0”.
To shut o
Turn the operation handle
j
to position "0". The automatic
ignitor is thereby shut o.
Switch o the fan (set the rotary switch to "0").
Close the bottle valve and the quick-close valve if the unit is not
used for a longer period of time.
1
During initial operation of the heating system, the-
re will be a slight nuisance caused by smoke and
odours. Immediately turn the operating handle
j
on
the heating to position „5“ and set the circulation fan
to the highest position. Open all doors and windows
and air the caravan well. The smoke and odours will
disperse after a short while.
Knob with thermostat and ignition