Operation Manual

Electrical Installations
07-2
•Unclampthebatterycircuitbreakeriftheancillarybattery
isnotbeingusedforalongperiodoftime(morethan1-2
months).Evenifthebatterycircuitbreakerisinterrupted,
thebatterycanstillbechargedbythebatterycharger(con-
servationcharging).
• Shouldtheconsumerbatteryberemoved,isolatetheplus
pole(topreventshortcircuitswhenturningonthemotor).
Battery charger
• Thecharger’scapacityis360W.
• ThechargerfunctionsinaccordancewithIU0U1charging
technology.
• Inthecaseofmisusetheguaranteeandmanufacturer’s
liabilitywillnolongerapply.
• TheairventsintheFIATseatconsolepanelmustnotbe
covereduporclosed.Ensurethatthereissucientventila-
tion.
Tank probes
Theprobewithrodsmeasuresthecontentsofthefreshand
wastewatertanks.
• Toavoidincrustations,particularlyinthewastewatertank,
neverletthewaterinthetanksstandfortoolong.
• Flushthetanksregularly.
230V automatic circuit breaker with an earth leakage
circuit breaker
The230Vautomaticcircuitbreakersuppliesandprotectsthe
230Vdevices.
• Toswitchothe230Vpowersupplyintheentiresystem,
setthe230Vautomaticcircuitbreakerto“0”(OFF).
Fuses
• Onlyreplacedefectivefusesafterthecauseofthedefect
hasbeenremediedbyaprofessionalelectrician.
• Thenewfusemusthavethesameamperageastheold
one.