User Manual
12
Setting Jumpers
Setting the Pulse Counter (PULSE2 & PULSE1 jumpers)
The motion detector is equipped with a programmable pulse counter which can be set to count 1,3 or 5
pulses. Place the pulse count jumpers at the desired setting as shown below.
Working mode (TEST & NORMAL jumpers)
To save battery power in normal use, if the detector is triggered twice within 3 minutes, it enters
sleeping state immediately. During this period, any movement detected does not generate an alarm.
After no movement within the next 3 minutes, it goes back to working state again.
For effective walk testing, set jumpers as shown on the right.
When walk testing is done, set jumpers to save power as shown on the right .
LED jumper
CLOSED enables LED on.
Battery receptacle
Contains three AA 1.5V
battery.
Inside view
Setting jumpers
Power on/off
Slide it up to ON to
power up the detector.
TEST
NORMAL
TEST
NORMAL
OPEN
CLOSED
1
2
3
4
6
5
PART OF INFRARED
SENSITIVE BEAM
ARRAY
Crossing one beam
causes detection
Crossing 3 beams
causes detection
Crossing 5 beams
causes detection
FOR FAST CATCH
PERFORMANCE
FOR EXCELLENT
FALSE ALARM
PROTECTION
FOR MAXIMUM
FALSE ALARM
PROTECTION IN
HOSTILE
ENVIRONMENT
PULSE2
PULSE1
PULSE2
PULSE1
PULSE2
PULSE1