Data Sheet

Title
Drawing.
No.
UXM-30LXH-EWA Specification
C-42-04104
3/10
4.Rated specification
Product name Laser range finder
Type UXM-30LXH-EWA
Light source Semiconductor laser, λ = 905 nm, safety class of the laser = 1
Power supply voltage 10 to 30VDC
Steady-state current: 600 mA or less at 12 VDC, 300 mA or less at 24 VDC
Starting current: 1.5 A or less at 12 VDC, 0.75 A or less at 24 VDC
Heater in use (0°C or below): 1.25 A or less at 12 VDC, 1.25 A or less at 24 VDC
7.2 W or less (at steady-state)
Heater in use (0°C or below): 15 W or less at 12 VDC, 30 W or less at 24 VDC
Guaranteed value of detection: 0.1 to 30 m
*1
(Reflectance of 10%, black paper, 500 mm × 500 mm)
0.1 to 80 m
*1
(Reflectance of 90%, white Kent paper, 1,000 mm × 1,500 mm)
Maximum detecting distance: 120 m
Minimum object to be detected : 33 mm (5 m), 65 mm (10 m), 200 mm (30 m)
10% reflectance, black paper, 0.1 to 15 m: ±30 mm, 15 to 30 m: ±50 mm*
1
0.1 to 30 m: ±50 mm
*2
Ambient illuminance: 3,000 lux or less
0.1 to 20 m50 mm
*2
Ambient illuminance: 100,000 lux or less
90% reflectance, white Kent paper, 0.1 to 30 m: ±30 mm*
1
0.1 to 30 m: ±50mm
*2
Ambient illuminance: 3,000 lux or less
0.1 to 30 m: ±50mm
*2
Ambient illuminance: 100,000 lux or less
Measurement resolution Unit of 1 mm
10% reflectance, black paper,
 
0.1 to 15 m: σ < 10 mm, 15 to 30 m: σ < 15 mm
*1
0.1 to 30 m: σ < 20 mm
*2
Ambient illuminance: 3,000 lux or less
0.1 to 20 m: σ < 30 mm
*2
Ambient illuminance: 100,000 lux or less
90% reflectance, white Kent paper, 0.1 to 30 m: σ < 10 mm*
1
0.1 to 30 m: σ < 15 mm
*2
Ambient illuminance: 3,000 lux or less
0.1 to 30 m: σ < 30 mm
*2
Ambient illuminance: 100,000 lux or less
Scanning angle 190°
Angular resolution Approx. 0.125° (360°/2880 divisions)
Scanning time 50 ms (rotating speed of motor: 1200 rpm)
Interface Ethernet 100BASE-TX (Auto-negotiation
Output OUTPUT 3 points: Synchronization master output, synchronization output, Malfunction output
Input INPUT 1 points: Synchronization input
Starting time Operation starts within 30 sec after turning on of power supply.
Indication lamp for power supply and operation (green), indication lamp for communication
measurement (orange)
Regarding the operation of indication lamps, refer to sub-clause 7.2.
Ambient operating
temperature, humidity
-10 to +50°C 85%RH
-30 to +50°C 85%RH (Heater in use)
However, dew condensation and freezing should not exist.
Resistance to weather
Detecting distance becomes shorter due to rain, snow, and sunlight.
*3
10 to 55 Hz, plural amplitude: 1.5 mm in X, Y, Z directions, each 2 hours
55 to 200 Hz
 
19.6 m/s
2
Sweep: 2 minutes in X, Y, Z directions, each 1 hour
Resistance to shock
196 m/s
2
in X, Y, Z directions, each 10 times
Power supply current
Detecting distance and
object to be detected
Vibration resistance
Average accuracy by
distance
Indication lamp
Electric power
consumption
Repeat accuracy
Notes *
1
Indoor environment (fluorescent lamp, 1,000 lux or less)
*
2
Detection cannot be guaranteed when direct light (such as sunlight) enters the device.
*
3
Regarding the influence of environment, please confirm with the actual equipment.