Installation Guide

STEP 1 - Calculation:
* Measure height of sliding glass panels (14): ___________
* Subtract 3 1/16" from this measurement: ___________
* New measurement is the height from the threshold to the
center of the first Wall Puck Step 3.
STEP 4 - Mount First Wall Puck on “High Side” wall:
* Measure up from the threshold, the distance determined in
Step 1. Center Puck on the Centerline with the slot in the
vertical position and mark the hole location. See Detail B.
* Drill with a 3/16" drill bit. Enlarge hole through tile with
5/16” carbide bit to ensure screw will not crack tile.
* Install the Wall Puck (4 inside) with one M6 X 50mm screw,
(7a).
* Attach Wall Collar onto puck and tighten set screws to
secure Wall Collar, (4) in place.
* Sequence tightening of set screws as shown for best results.
Slider panel height - 3 1/16 = ______
B
Orient the
slot in Puck
vertically
when
securing.
High Side
Measurement
in Step 1
A
STEP 2 - Evaluate Threshold:
* Maximum recommended vertical threshold outage from
side to side is 1/4".
* If needed, mark high-side and low-side of threshold.
* First puck will be installed on high-side wall, or stationary
panel side if threshold is level.
* NOTE: Set sliding panel (14) inside shower before
proceeding.
Low (1/4” max)
High Side
Threshold
STEP 3 - Determine Centerline on Threshold and Walls:
* Mark Center Guide (5) location on threshold.
* To determine Centerline location, center the guide at center
of threshold width and depth.
Do not install! Location will shift during final adjustments.
* Wall pucks will be centered on the centerline of unit.
* Laser or plumb-bob is handy to determine and mark the
overall centerline of the unit. See Detail A
STEP 5 A - Check Header Tube Length:
* The header may already be cut to length from the factory
* To check measure wall to wall just below the Wall Pucks
and subtract 1 1/2". If your tube is this length, procede
to STEP 6. If not, procede to STEP 5B.
STEP 5 B - Cut Header Tube Length (figure C):
* Measure wall to wall just below the Wall Pucks
and subtract 1 3/4". This dimension will be the final length to
cut the header tube (11).
* IMPORTANT: The tube must be cut off from the end of the tube
that is furthest AWAY from the holes in the tube.
* Cut the tube to length with a hack saw.
Use 2” long
1/4” screw
C
Measure Wall to Wall just
below wall pucks subtract 1 3/4"
Wall Collar (4)
(orient cone
tipped set
screws into
puck)
Installation Instructions
Models: ECTE180 / ECSE180
3/8" Frameless Slider & 180° Panel
Page 4
Center
Guide (5)
set slider
panel (14)
Inside
shower
before
proceding
Cut from end that is opposite from the
holes in the tube
For STEP 5 B only