How to Guide
4 3/4"
26 1/2"
9"
2.25
3.88
7.50
21.50
.50
EXTRUDED THROUGH
FOR 1" COPPER.
.19
NAIL HOLES
.68
1.12
2.50
SLOTS & HOLES=
CLEARANCE FOR
5/8" BOLTS.
ALL DIMENSIONS IN INCHES
.75
23.25
4 3/4"
26 1/2"
9"
800-321-0316 OR 760-744-6944 / FAX: 760-744-0507 / WWW.HOLDRITE.COM
spec_114-CO_RevH
PRODUCT SPECIFICATION DRAWING
HOLDRITE® #114-CO
Supports flush valves on carriers
This heavy-gage Copper-Bonded™ #114-CO offset carrier bracket mounts directly
to a 4-bolt siphon jet closet carrier and positions the flush valve at 14" above the
top carrier mounting bolt, and offsets it 4-3/4" from the center of the carrier. A patent
pending "Figure 8" hole pattern on top provides 1/4" left or right offset for flush valve
support providing a single bracket to be used in a left or right hand installation while
providing the desired 4-3/4" center line rough-in. This installation typically places the
flush valve at 11-1/2" above the fixture. When soldering, heat the pipe, not the bracket.
Product Information:
Material: 16 gage CRS, Copper-Bonded™
•
Works with all 4 bolt siphon jet carriers
•
Unique flush valve support hole accommodates a 4-3/4" center line rough-in
•
Includes 1/2" holes for positioning various trap primers
•
Works with current #114-C-EXT brackets
•
UPC / IPC / IAPMO listed
•
THIS INFORMATION IS PROPRIETARY TO HOLDRITE AND IS SUBJECT
TO CHANGE WITHOUT NOTICE. IT MAY NOT BE REPRODUCED IN
PART OR WHOLE WITHOUT WRITTEN AUTHORIZATION.