Push Locator Whiskers until locked in place. (Optional, screw can be used to strengthen attachment) Twist Outer Sleeve, left or right, until locked in notches. 12" Hightest position (Sleeve extension can also be added) 8" Lowest position Pull out Locator Whiskers (optional) ADJUST TO DESIRED HEIGHT. (Fig. 1) LOCK OUTER SLEEVE IN PLACE. (Fig. 3) RE-INSTALL CAP & INSERT LOCATOR WHISKERS. (Fig. 4) CUT INNER & OUTER SLEEVE IF DESIRED HEIGHT IS UNDER 8". (CAN BE CUT AS SHORT AS 2-1/2") (Fig.
Turn Water Dam, clockwise. Pipe Turn Wrench, counter-clock-wise. REMOVE CAP WITH HF WRENCH, OR BREAK-OUT WITH HAMMER. (SLEEVE SHOWN POURED IN CONCRETE) (Fig. 1) INSTALL 2" TALL WATER DAM. (ADD THREAD SEALANT IF DESIRED) (Fig. 2) INSTALL PIPE FROM BELOW. (SOAPY WATER EASES PIPE INSERTION) (Fig. 3) Hydroflame PRO Series - Water Dam Installation. See Hydroflame Pro - "Best Practices" document and UL's online certification directory (file R25101) for more details.
Tub Box Tub Box Assy Adapter Fitting (Rotate to lock into Sleeve notches) Sleeve CUT INNER SLEEVE TO DESIRED HEIGHT. (IF NEEDED) (SLEEVE EXTENSION CAN ALSO BE ADDED, FOR DESIRE HEIGHT OVER 10-3/4") (Fig. 1) Tub Box Legs & Feet, (2 each). Cut legs to length, even with Tub Box Assy. Glue to tub box. ATTACH TUB BOX ADAPTER TO SLEEVE. GLUE ABS ADAPTER TO TUB BOX. (Fig. 2) INSTALL REAR LEGS. CUT TO HEIGHT. (IF NEEDED) (10-3/4" TALL w/o MODIFICATIONS) (Fig. 3) REMOVE STYROFOAM BLOCK & "KNOCK OUT PLUG".
8" Lowest position Screw Adapter Box into Outer Sleeve (Styrofoam block included) Twist Outer Sleeve, left or right, until locked in notches. 12" Hightest position (Sleeve extension can also be added) ADJUST TO DESIRED HEIGHT. (ACCOUNT FOR AERATOR BOX HEIGHT OF 4") (Fig. 1) LOCK OUTER SLEEVE IN PLACE. (Fig. 3) CUT INNER & OUTER SLEEVE (IF NEEDED). CAN BE CUT AS SHORT AS 2-1/2". (Fig. 2) INSTALL AERATOR ADAPTER. (BOX "INVERTED") (Fig.
Plastic Closet Flange Note: Glue closet flange onto pipe. Turn Wrench, counter-clock-wise. REMOVE CAP WITH HF WRENCH, OR BREAK-OUT WITH HAMMER. (SLEEVE SHOWN POURED IN CONCRETE) (Fig. 1) INSERT PLASTIC CLOSET FLANGE & PIPE. (Fig. 2) Hydroflame PRO Series - Installation of Plastic Closet Flange (3" or 4"). See Hydroflame Pro - "Best Practices" document and UL's online certification directory (file R25101) for more details.
Push Locator Whiskers until locked in place. (Optional, screw can be used to strengthen attachment) Note: Push Cap down onto Sleeve until it snaps on. Rotate clockwise, slightly, if sesired. Pull out Locator Whiskers (optional) BASIC SLEEVE. "-B" VERSION, 7 ¾" TALL. (Fig. 1) CUT SLEEVE, IF DESIRED HEIGHT IS UNDER 7-3/4". (CAN BE CUT AS SHORT AS 2-1/2") (Fig. 2) RE-INSTALL CAP & INSERT LOCATOR WHISKERS. (Fig. 3) Pipe Pour concrete. Turn Wrench, counter-clock-wise.
Snap CD Plate to bottom of Base, 12 places. (Optional, #8 screws may be used to increase attachment strength) REMOVE OUTER SLEEVE & UNSCREW CAP. (Fig. 1) INSTALL CD PLATE. (Fig. 3) CUT SLEEVE TO DESIRED HEIGHT. (CAN BE CUT AS SHORT AS 2-1/2") (Fig. 2) Snap Cap & Locator Whiskers onto Sleeve. (Optional, screw can be used to strenghten attachment. Note: Push Cap down onto Sleeve until it snaps on. Rotate clockwise, slightly, if sesired.
Screws, 4 places recommended Pour concrete. Corrugated Deck POUR CONCRETE. (Fig. 8) INSTALL SLEEVE ASSY INTO CORRUGATED DECK. (Fig. 7) Pipe Turn Wrench, counter-clock-wise. REMOVE CAP WITH HF WRENCH, OR BREAK-OUT WITH HAMMER. (Fig. 9) INSTALL PIPE FROM BELOW. (SOAPY WATER EASES PIPE INSERTION) (Fig. 10) Hydroflame PRO Series - Metal Deck (pg. 2 of 2). See Hydroflame Pro - "Best Practices" document and UL's online certification directory (file R25101) for more details.
Snap CD Plate onto bottom of Base. (Optional, #8 screws may be used to increase attachment strength.) REMOVE OUTER SLEEVE & UNSCREW CAP. (Fig. 1) INSTALL CD PLATE. (Fig. 3) CUT SLEEVE TO DESIRED HEIGHT. (CAN BE CUT AS SHORT AS 4-1/2") (Fig. 2) Snap Cap & Locator Whiskers onto Sleeve. (Optional, screw can be used, for stronger attachment) Note: Push Cap down onto Sleeve until it snaps on. Rotate clockwise, slightly, if sesired.
Pour concrete. Turn Wrench, counter-clock-wise. Screw, 4 places recommended. Corrugated Deck POUR CONCRETE. (Fig. 8) REMOVE CAP WITH HF WRENCH, OR BREAK-OUT WITH HAMMER. (Fig. 9) Fire Caulking, as reqired. INSTALL SLEEVE ASSY INTO CORRUGATED DECK. (Fig. 7) Backing Material, as required. Pipe INSTALL PIPE FROM BELOW, INSTALL BACKING MATERIAL & FIRE CAULKING AS REQUIRED. (SOAPY WATER EASES PIPE INSERTION) (Fig. 10) Hydroflame PRO Series - Hollow Sleeve on Metal Deck (pg. 2 of 2).
Twist Outer Sleeve, left or right, until locked in notches. 12" Hightest position (Sleeve extension can also be added) 8" Lowest position Push Locator Whiskers until locked in place. (Optional, screw can be used for stronger attachment). Pull out Locator Whiskers (optional) ADJUST TO DESIRED HEIGHT. (CAN BE CUT AS SHORT AS 4-1/2") (Fig. 1) CUT INNER & OUTER SLEEVE IF DESIRED HEIGHT IS UNDER 8". (Fig. 2) LOCK OUTER SLEEVE IN PLACE. (Fig. 3) RE-INSTALL CAP & INSERT WHISKERS. (Fig.
Twist Outer Sleeve, left or right, until locked in notches. 12" Hightest position (Sleeve extension can also be added) 8" Lowest position CUT INNER & OUTER SLEEVE. (AS NEEDED) (MIN. 4-1/2" TOTAL SLAB THICKNESS) (Fig. 2) ADJUST TO DESIRED HEIGHT. (Fig. 1) LOCK OUTER SLEEVE IN PLACE. (NON-TELESCOPING "-B" VERSION SLEEVE CAN ALSO BE USED) (Fig. 3) Concrete. Nail, 4 places recommended Floor Drain POUR CONCRETE. (Fig. 7) NAIL TO FORM DECK. (Fig.
Cast Iron Closet Flange No-Hub Coupling Turn Wrench, counter-clock-wise. Pipe REMOVE CAP WITH HF WRENCH, OR BREAK-OUT WITH HAMMER. (SLEEVE SHOWN POURED IN CONCRETE) (Fig. 1) INSERT CAST IRON CLOSET FLANGE & PIPE. (Fig. 2) Hydroflame PRO Series - Installation of Cast Iron Closet Flange (3" or 4"). See Hydroflame Pro - "Best Practices" document and UL's online certification directory (file R25101) for more details.
Twist Outer Sleeve, left or right, until locked in notches. 12" Hightest position (Sleeve extension can also be added) 8" Lowest position CUT INNER & OUTER SLEEVE. (AS NEEDED) (CAN BE CUT AS SHORT AS 4-1/2") (Fig. 2) ADJUST TO DESIRED HEIGHT. (Fig. 1) Nail, 4 places recommended LOCK OUTER SLEEVE IN PLACE. (Fig. 3) Concrete NAIL TO FORM DECK. (Fig. 4) Fire Caulking as required. Turn Wrench, counter-clock-wise Backing Material, as required. Cables or Pipes POUR CONCRETE. (Fig.
Twist Outer Sleeve, left or right, until locked in notches. 12" Hightest position (Sleeve extension can also be added) 8" Lowest position CUT INNER & OUTER SLEEVE AS NEEDED, TO ACCOUNT FOR AERATOR BOX HEIGHT. (CAN BE CUT AS SHORT AS 2-1/2") (Fig. 2) ADJUST TO DESIRED HEIGHT, ACCOUNT FOR AERATOR BOX HEIGHT. (Fig. 1) LOCK OUTER SLEEVE IN PLACE. (NON-TELESCOPING "-B" VERSION SLEEVE CAN ALSO BE USED) (Fig. 3) Push Locator Whiskers until locked in place.