N Motor Capacitor Sizing Chart
Pump Model Start Capacitor Run Capacitor Cap Kits
AMX334-434/1-142/2.9N 80µf @ 330V 40µf @ 370V 8857010
AMX334-434/1-155/4N 100µf @ 330V 50µf @ 370V 8857035
AMX334-434/1-178/4N 100µf @ 330V 50µf @ 370V 8857035
AMX334-434/1-184/5N 150µf @ 330V 80µf @ 370V 8857040
AMX334-434/1-193/5N 150µf @ 330V 80µf @ 370V 8857040
AMX334-434/1-193/7N 150µf @ 330V 100µf @ 370V† 8857045
AMX334-434/1-206/7N 150µf @ 330V 100µf @ 370V† 8857045
AMX334-434/1-206/10N 250µf @ 330V** 120µf @ 370V* 8857055
AMX334-434/1-218/10N 250µf @ 330V** 120µf @ 370V* 8857055
AMX334-434/1-228/10N 250µf @ 330V** 120µf @ 370V* 8857055
* (2) 60µf run capacitors in parallel are required.
†(2) 50µf run capacitors in parallel are required.
** (1) 150µf & 100µf start capacitor in parallel required.
*Consult factory for A Frame motors with centrifugal switch.
External Seal Probe Wiring
Seal Probes must be connected to a Homa Go Switch or suitable controller to operate.