Seal Probe Installation
The Mechanical Seal Leak Detection probe is shipped loose to protect from damage.
Please follow this procedure to install the probe.
1) Lay pump on its side with the plug on the seal chamber facing upwards.
2) Unscrew the plug with the proper wrench, taking care not to damage the sealing
surface.
3) Verify that seal chamber oil level is within ¼” of the indicated value. Measurement is
from oil level to the top of hole. See IOM Manual for seal chamber oil volume, if
required.
4) Remove the new sealing gasket from package and install it onto the seal probe plug.
5) Install the seal probe with gasket into the opening, taking care not to damage the
cable. Then tighten the seal probe with the proper wrench until snug. Do not
overtighten. Once tight, verify the seal gasket is properly seated and the cable is not
pinched or twisted. NOTE: At installation of the seal probe be careful not to bind the
seal probe cord as it is being installed into the pump.
6) Lift pump into a vertical position and inspect for any leaks. Secure seal probe cable to
pump and power cable with tyraps before installing pump.
OR
Proof
Standard
Plug