TROUBLESHOOTING
DANGER: Risk of severe injury by electric shock or death by electrocution. Disconnect power before servicing.
Blower does not come on:
Hose from blower to button is disconnected. Reconnect.
Hose disconnected from blower. Reconnect.
Breaker at main power supply tripped or malfunctioned. Reset or replace breaker.
GFCI tripped or malfunctioning. Reset or replace.
Power cord not plugged in. Plug cord into GFCI.
No bubbles from jets:
Debris blocking bubbles from one or two jets. Use soft bristled toothbrush to loosen debris.
Return line is higher than the normal waterline. Contact installer it correct elevation of return line.
Low Voltage. Contact electrician to correct wiring.
Blower Shutting O:
Overheating. Let blower cool. Increase ventilation around blower.
Blower has automatically timed out. Press button to turn back on.
Breaker at power supply or GFCI tripped or malfunctioned. Reset or replace GFCI.
Bath is wired on shared circuit or with an extension cord. Contact electrician to correct wiring.
Rust colored ring in bath:
Sediment in water heater. Flush water heater and clean bath with grease cutting dish soap.