Installation Guide

Page 3
Venting Requirements
Vent system must terminate to the out-
side (roof or side wall), unless using a
recirculating kit.
Do not terminate the vent system in an
attic or other enclosed area.
Do not use 4” (10.2 cm) laundry-type
wall caps.
Use metal/aluminum vent only. Rigid
metal/aluminum vent is recommended.
Do not use plastic vent.
Always keep the duct clean to ensure
proper airflow.
Calculate the following figures before
installation:
Distance from the floor to the ceil-1.
ing.
Distance between the floor to the 2.
countertop/stove (recommend 24in
to 30in).
Distance between the countertop/3.
stove to the range hood.
Height of hood and duct cover.4.
For the most efficient and quiet
operation:
It is recommended that the range hood
be vented vertically through the roof
through 6” (15 cm) round metal/ alu-
minum vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24”
(61 cm) of straight vent between the
elbows if more than one elbow is used.
Do Not install two elbows together.
The length of vent system and number
of elbows should be kept to a mini-
mum to provide efficient performance.
The vent system must have a damper.
If roof or wall cap has a damper, Do
Not use damper supplied with the
range hood.
Use duct tape to seal all joints in the
vent system.
Use caulking to seal exterior wall or
roof opening around the cap.
Height & Clearance
Cabinet
Range hood
Venting Pipe
36” base
Min:
24”
Max: 30”