SDS

_____________________________________________________________________________________________
1485034 - GD Midea LR03 Battery Revision Date 29-Oct-2018
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep out of the reach
of children. Protect from moisture. Store locked up. Store away from other materials.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Zinc
7440-66-6
STEL: 10 mg/m
3
respirable
fraction
TWA: 2 mg/m
3
respirable
fraction
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable
fraction
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume
STEL: 10 mg/m
3
fume
Manganese
7439-96-5
TWA: 0.02 mg/m
3
respirable
particulate matter
TWA: 0.1 mg/m
3
inhalable
particulate matter
(vacated) TWA: 1 mg/m
3
fume
(vacated) STEL: 3 mg/m
3
fume
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
fume
IDLH: 500 mg/m
3
TWA: 1 mg/m
3
fume
STEL: 3 mg/m
3
Zinc chloride
7646-85-7
STEL: 2 mg/m
3
fume
TWA: 1 mg/m
3
fume
TWA: 1 mg/m
3
fume
(vacated) TWA: 1 mg/m
3
fume
(vacated) STEL: 2 mg/m
3
fume
IDLH: 50 mg/m
3
fume
TWA: 1 mg/m
3
fume
STEL: 2 mg/m
3
fume
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume
and mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Carbon black
1333-86-4
TWA: 3 mg/m
3
inhalable
particulate matter
TWA: 3.5 mg/m
3
(vacated) TWA: 3.5 mg/m
3
IDLH: 1750 mg/m
3
TWA: 3.5 mg/m
3
TWA: 0.1 mg/m
3
Carbon black
in presence of Polycyclic
aromatic hydrocarbons PAH
Ammonium chloride
12125-02-9
STEL: 20 mg/m
3
fume
TWA: 10 mg/m
3
fume
(vacated) TWA: 10 mg/m
3
fume
(vacated) STEL: 20 mg/m
3
fume
TWA: 10 mg/m
3
fume
STEL: 20 mg/m
3
fume
Chemical name Alberta British Columbia Ontario TWAEV Quebec
Manganese
7439-96-5
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
Zinc chloride
7646-85-7
TWA: 1 mg/m
3
STEL: 2 mg/m
3
TWA: 1 mg/m
3
STEL: 2 mg/m
3
TWA: 1 mg/m
3
STEL: 2 mg/m
3
TWA: 1 mg/m
3
Copper
7440-50-8
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
TWA: 1 mg/m
3
TWA: 0.2 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
TWA: 0.2 mg/m
3
TWA: 1 mg/m
3
Carbon black
1333-86-4
TWA: 3.5 mg/m
3
TWA: 3 mg/m
3
TWA: 3 mg/m
3
TWA: 3.5 mg/m
3
Ammonium chloride
12125-02-9
TWA: 10 mg/m
3
STEL: 20 mg/m
3
TWA: 10 mg/m
3
STEL: 20 mg/m
3
TWA: 10 mg/m
3
STEL: 20 mg/m
3
TWA: 10 mg/m
3
STEL: 20 mg/m
3
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992).
Appropriate engineering controls
Engineering controls
Showers
Eyewash stations
Ventilation systems.
_____________________________________________________________________________________________
Page 5 / 13