Instructions / Assembly

LEAK CHECK
17
Operation (continued)
HOMEDEPOT.COM/HOMEDECORATORS
Please contact 1-800-986-3460 for further assistance.
NOTE: Whenever gas connections are loosened or removed,
you must perform a complete leak test.
REGULATOR / CYLINDER
CONNECTION
HOSE / REGULATOR
CONNECTION
WARNING:
Perform all leak tests outdoors.
Extinguish all open flames.
NEVER leak test when smoking.
Do not use the heater until all connections have been
leak tested and do not leak.
Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles continue
Complete installation.
appearing, the hose should be returned to the place of purchase.
Apply several drops of solution where hose attaches to regulator.
Apply several drops of solution where regulator connects to cylinder.
Make sure all patio heater and light valves are OFF.
Turn cylinder valve ON.
Turn cylinder valve OFF.
If bubbles appear at any connection, there is a leak.
If NO bubbles appear at any connection, the connections are secure.
If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several attempts, cylinder value is defective and should be
returned to cylinder’s place of purchase.