5
TANK/GAS LINE CONNECTION LEAK TEST
Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three parts water.
Make sure the control knob is in the “OFF” position.
Connect LP gas tank per “CONNECTING LP GAS TANK” SECTION.
Turn LP gas tank valve to “OPEN”.
Spoon several drops of solution, or use a squirt bottle, at all “X” locations (Figure 1 and 2 on the previous page).
a) If any bubbles appear, turn LP gas tank valve to “CLOSED”, reconnect and re-test.
b) If you continue to see bubbles after several attempts, turn LP gas tank valve to “CLOSED” and disconnect
LP gas tank, per “DISCONNECTING LP GAS TANK”.
c) If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED”, wipe away solution and proceed.