Instructions / Assembly

6
GROUNDING INSTRUCTIONS
This heater is for use with 120V power sources. The cord has a three-blade, grounding-type
plug. An adapter is available for connecting three-blade grounding-type plugs to two-slot
receptacles. The green grounding lug extending from the adapter must be connected to a
permanent ground, such as a properly grounded outlet box. The adapter should not be used if
a three-slot grounded receptacle is available.
DETERMINING THE MOUNTING LOCATION
When choosing a location for your new fireplace, ensure the general instructions are followed.
For the best effect, install the fireplace out of direct sunlight. It is safe to set the fireplace
insert close to non-combustibles.
WARNING: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
FIREBOX SPECIFICATIONS
ELECTRICAL CONNECTION
A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required to operate this appliance. Preferably, the fireplace insert
will be on a dedicated circuit, as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when
the heater is in operation. The unit comes standard with a 6 ft (1.8 m) long 3-wire cord, exiting out the back of the fireplace insert. Plan
the installation to avoid the use of an extension cord. If an extension cord must be used, it must be a minimum 14-gauge, 3-wire with
grounding type plug and connector, and must be rated not less than 1875 watts. The extension cord shall not be more than 20 ft (6 m) in
length.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce
the risk of fire, electrical shock, and injury to persons.
WARNING: Do not use this fireplace insert if any part of it has been under water. Immediately call a qualified service technician to inspect the
firebox and replace any part of the electrical system which has been under water.
GLASS INFORMATION
1. Under no circumstances should this product be operated with a broken or chipped glass panel.
2. Do not strike or slam the glass.
3. Do not use abrasive cleansers to clean the glass.
4. This product uses tempered glass. Replacement of the glass supplied by the manufacturer should be done by qualified/authorized
service personnel only.
Pre-Assembly (continued)
Model No. MFB25WSC-1
Dimensions W x D x H 25 in. x 10.4 in. x 18.5 in. (63.3 cm x 26.5 cm x 47 cm)
Net Weight / Gross Weight 27.7 lbs / 31 lbs (12.6 kg / 14.1 kg)
Voltage 120V
Frequency 60 Hz
Watts / Amps 1400 W / 11.6 A
Fireplace Rating 1400 W / 4777 BTUs
Adapter
Grounding Lug
Cover of Grounded Outlet Box
Grounding Pin
Cover of Grounded Outlet Box
Metal
Screw