SDS

_____________________________________________________________________________________________
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Manganese dioxide
1313-13-9
TWA: 0.02 mg/m
3
Mn
TWA: 0.1 mg/m
3
Mn
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn
TWA: 1 mg/m
3
Mn
STEL: 3 mg/m
3
Mn
Zinc
7440-66-6
STEL: 10 mg/m
3
respirable
fraction
TWA: 2 mg/m
3
respirable fraction
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume
STEL: 10 mg/m
3
fume
Potassium hydroxide
1310-58-3
Ceiling: 2 mg/m
3
(vacated) Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
_____________________________________________________________________________________________
7. HANDLING AND STORAGE
Precautions for safe handling
Handling
In case of rupture. Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Use personal protection equipment.
Conditions for safe storage, including any incompatibilities
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from
moisture. Store locked up. Keep out of the reach of children. Store away from other
materials.
Incompatible Products
Acids. Bases. Oxidizing agent.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions
Attention! Corrosive material. Avoid contact with skin, eyes or clothing. Ensure adequate
ventilation. Use personal protective equipment as required. Evacuate personnel to safe
areas. Keep people away from and upwind of spill/leak. Avoid generation of dust. Do not
breathe dust.
Other Information
Refer to protective measures listed in Sections 7 and 8.
Environmental precautions
Environmental precautions
Prevent further leakage or spillage if safe to do so. Should not be released into the
environment. Do not allow to enter into soil/subsoil. Prevent product from entering drains.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Pick up and transfer to properly labeled containers.
Revision Date 12-May-2015
Page 5 / 13
1240113 - Alkaline Battery LR03 Wuxi Noran Battery Co Ltd