Installation Practices
Termination Fitting Assembly (Parts 11-464-XXX)
Step 1 Cut HOME-FLEX® tubing to length
Route CSST through structure to the desired
location of the termination ange. Bend
tubing as required so it exits the structure in
desired direction of the termination plate.
Cut the excess CSST so about 2" of tubing
extends beyond the wall.
Step 2 Remove tubing jacket to prepare for tting
assembly
Using a utility knife, strip the yellow tubing
jacket back 2 valleys from the end of the
tubing. Also remove the yellow warning
label from the tting assembly.
DO NOT use a tube cutter.
Step 3 Place ange nut over HOME-FLEX® tubing
Slide the termination ange over the tubing
with the threaded end pointing toward the
end of the tubing.
DO NOT SECURE THE FLANGE.
Step 4 Place retainer ring on HOME-FLEX® tubing
Place the retainer ring in the rst valley of the
tubing. Being careful to not dent the tubing,
clamp the retainer ring in place by applying
gentle pressure 360° around the ring. It
should t tightly and not easily spin around
the tubing.