Specification

Perfect Water Technologies, INC.
7701 E. Gray Rd. Suite #109 Scottsdale, AZ 85260
1-877-693-7873
Support@ThePerfectwater.com
Performance Data Sheet
HOME MASTER® HM-MINI-PLUS MINI PLUS SYSTEM
This system has been tested according to NSF/ANSI 42 and 53 for reduction of the contaminate
listed below. The concentration of the indicated contaminate in water entering the system was
reduced to a concentration less than or equal to the US EPA permissible MCL limit of 15
micrograms/liter for water leaving the drinking water system as specified in NSF/ANSI 42 and 53.
While testing was performed under standard laboratory conditions, actual performance may vary.
The Home Master
® MINI Filter met standard testing requirements for cyst reduction and may be
used on disinfected waters that may contain filterable cysts.
*Performance Data Table
Contaminate
USEPA
MCL
Influent
challenge
Concentration
Reduction
Requirement
Average
Percent
Reduction
Minimum
Percent
Reduction
Chlorine,
Taste & Odor
- 2.0 mg/L ± 10%;
2.22 ppm
≥50% 97.3% 97%
Cyst 99.95%
reduction
Minimum
50,000/L;
104,457 particles
99.95% 99.95% 99.99%
Lead (Pb) pH
8.5
Lead (Pb) pH
6.5
15 µg/L
15 µg/L
135 µg/L
149 µg/L
13 µg/L
1 µg/L
95.9%
99%
90%
99%
*Tested under the following parameters: Flow Rate = 0.5 gpm; Pressure = 60psig; pH = 8.5 and 6.5;
Temp = 20 ± 2.5ºC
Operating Specifications:
Capacity: 750 Gallons
Flow Rate: 0.50 GPM (1.89 LPM)
Maximum Pressure: 125 PSIG
Temperature: 35°-100° F (1.66° - 37.77º C)
General Installation/Operation/Maintenance Requirements:
Note Flow Direction of filter
Flush new cartridge with 5 gallons of water prior to use and check for leaks
Install in compliance with state and local laws and regulations
Special Notices:
The contaminants or other substances removed or reduced by this water filter are not
necessarily in your water
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the filter