Perfect Water Technologies Home Master® Reverse Osmosis System Installation & Service Manual Home Home Home Home Home Master® Master® Master® Master® Master® Standard RO Full Contact® Artesian IRON ULTRA HydroPerfection® Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual Home Master® RO Contents: 1 1 1 1 1 1 1 1 Assembled RO filter cluster Storage tank Tank valve Drain saddle & gasket Roll Teflon tape Mounting clip & screw Long reach RO faucet with mounting hardware. EZ adapter—feed water adapter 3/8” mc x 3/8” fc x 1/4” tube General System Specifications • • • • • • Feed water: PSI 40 - 100 PSI (if on a private well, please increase well pump pressure) Feed water Temperature: 40˚ - 100˚(F) Max.
Home Master® Reverse Osmosis System—Owners Manual Drilling hole for RO faucet WARNING: Serious cracking and damage may occur to your sink even if instructions are followed exactly due to age and the imperfections inherent in natural materials. Instructions may not apply exactly to your sink. Use caution – sink may be slippery. 1. Remove base cover plate from RO faucet packaging. Line-up base cover plate with other sink faucets. Check underside of sink for spacing from trim, curvatures, and other obstacles.
Home Master® Reverse Osmosis System—Owners Manual 2. Install EZ adapter on cold water line - Always wear protective eyewear. Locate the cold water angle-stop (the main water lines under the sink – one hot water, one cold water), and turn clock-wise to shut off the water. Locate 3/8” fitting, typically found on the line out of the angle-stop or where the existing line connects to the kitchen faucet. Disconnect the 3/8” fitting on either the angle-stop or the kitchen faucet.
Home Master® Reverse Osmosis System—Owners Manual 4. Mount the Home Master® RO - Identify location for installing mounting clip to hang the Home Master® RO filter cluster. Location should allow room for the reserve tank, for connecting and disconnecting the unit, and enough room for performing general service on the unit. Use supplied mounting clip and mounting template located inside back cover. Home Master® RO should be mounted vertically where the drain line out is on the bottom.
Home Master® Reverse Osmosis System—Owners Manual the handle will be perpendicular to the body until after the fill and drain procedure (step 9) has been performed at least twice. Also remember to dump the remaining ice and flush the water center prior to use. 5. Affix product label found in the parts bag to the top of the reserve tank. 6.
Home Master® Reverse Osmosis System—Owners Manual loops are above the drain saddle. Hand tighten black plastic nut onto the drain saddle male fitting until it is snug. Do not over tighten and please DO NOT add a tubing insert. Drain — Garbage Disposal Drain Connection: Insert RED 1/4” tubing into 1/4” push-in fitting built-into Garbage Disposal Drain Adapter. Push tubing all the way in, then pull back gently to check fit. Push twice to be sure its really in. 8.
Home Master® Reverse Osmosis System—Owners Manual Troubleshooting IMPORTANT NOTE: Before performing service on the Home Master® RO at any time, and for any reason: first close all under-sink water valves, except for the RO faucet, which you should open to relieve system pressure and drain away excess water from the lines. Pushpull and quick connect fittings are nearly impossible to remove when under pressure. Leaks from metal fittings Unscrew fittings and re-tape male fitting.
Home Master® Reverse Osmosis System—Owners Manual drainage C) Use a common rubber stopper to cover your sink’s drain opening to muffle the sound. Weak pressure at RO faucet & Reserve tank filling slowly NOTE: Seasonal changes in temperature can cause pressure imbalances within the system resulting in slow water production. Oftentimes the imbalance will correct itself on its own within a few days.
Home Master® Reverse Osmosis System—Owners Manual can also unscrew the grey elbow at the bottom of the membrane housing. If gunk is obstructing the drain line, then the system cannot produce good water. 3. If the flow to the membrane housing is weak, then start working your way backward and check each connection point until you find the blockage point. At each point - turn off the water at the EZ adapter and tank, and briefly turn on the RO faucet at the sink to relieve any system pressure.
Home Master® Reverse Osmosis System—Owners Manual foods. Close valve feeding the fridge and taste the RO water. If good, then its likely not a problem with the RO system directly. Flush & Drain water center, dump at least 2 batches of ice, dispose of foods/leftovers/condiments that are out of code, sanitize shelves and all surfaces. Seal and reseal recent leftovers and frozen goods. Call for support if poor taste persists.
Home Master® Reverse Osmosis System—Owners Manual USING QUICK CONNECT FITTINGS Page 12 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual Page 13 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual SAMPLE SCHEMATICS Have a problem? Call us 877-693-7873 We want to be part of the solution ______________________________________ Page 14 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual Page 15 Customer Service Hotline 1-877-693-PURE
Home Master® Reverse Osmosis System—Owners Manual 10 Tips for an Easy and Successful Installation 1. Keep it simple - there are 4 connections to make, and the tubing is color coded. VIDEO INSTRUCTIONS ARE AVAILABLE ONLINE 2. Have plenty of time, light, space, and towels before getting started. If everything goes well, you should be done in 45 minutes. However, if your feed water line is a different size, or if you don’t have an extra hole for the faucet, it can take somewhat longer. 3.