ATTACHING THE RESTING FOOT
See Figure 3.
 Lift the machine slightly. Slide the resting foot into the 
bottom of the spray wand storage tube.
  Push the resting foot into the storage tube until the base 
of the machine rests in the grooves on top of the resting 
foot.
ASSEMBLING THE SPRAY WAND
See Figure 4.
To attach the assist handle assembly:
 Remove the wing nut from the assist handle assembly 
then slide the spray wand assembly onto the assist handle  
assembly bracket.
  NOTE: The smooth side of the assist handle assembly 
can be facing down or up.
 Position the assist handle between the ribs of the spray 
wand aligning the tab and the detent.
 Secure the assist handle in place by tightening the wing 
nut.
To attach the spray wand extension:
 Place  the  threaded  end  of  the  wand  extension  in  the 
connector on the end of the spray wand assembly. Push 
until it snaps into place.
 Turn the connector clockwise until it stops. This secures 
the wand extension in place.
 When not in use, place the assembled spray wand into 
the spray wand storage.
CONNECTING  HIGH  PRESSURE  HOSE  TO  
SPRAY WAND ASSEMBLY
See Figure 5.
 Uncoil the high pressure hose.
 Pull back and hold the quick-connect collar on the high 
pressure hose.
 Insert the inlet coupler on the spray wand handle into the 
collar.
 Release the collar and push until it clicks.
 Pull on the hose to be certain it is properly secured.
ATTACHING INJECTION HOSE
See Figure 6.
Before  detergent can  be used with this machine, the 
injection hose must be attached.
 Uncoil the clear injection hose.
 Push the open end of the injection hose securely over the 
barbed fitting.
 Lift the chemical bucket and push the injection hose into 
the slot on the back of the bucket.
 Replace the bucket in the bucket holder.
Fig. 4
Fig. 5
QUICK-
CONNECT 
COLLAR
HIGH 
PRESSURE 
HOSE
INLET 
COUPLER
ASSIST 
HANDLE 
ASSEMBLY
SPRAY 
WAND
EXTENSION
CONNECTOR
SPRAY 
WAND
RESTING 
FOOT
Fig. 3
RIBS
TAB
DETENT
ASSEMBLY