MSDS

MSDS- Page 4of 8
RJS STANDARDS TESTING & CERTIFICATION CENTER
141-04 14th Avenue, Whitestone, New York 11357, USA.
Use of full length sleeves and pants; boots or work shoes are recommended for manufacturing operations.
Storage: Store in cool (15~30), dry, well ventilated area and away from combustible materials, sources of ignition,
excessive heat and direct sunlight. Do not store in sealed areas. Avoid overheating and overcharging.
Warning: Not for use on children under 5 years old.
Exposure limit:
Lead, Lead Compounds (Chronic poison):
OSHA - PEL 0.05 mg/m
3
ACGIH - TLV 0.05 mg/m
3
NIOSH - REL<0.10mg/m
3
Sulfuric Acid (suspected human carcinogen for sulfuric acid contained in strong inorganic acid):
OSHA - PEL 1mg/m
3
(TWA)
ACGIH - TLV 1mg/m
3
(TWA), 3mg/m
3
(STEL)
NIOSH - REL 1.0mg/m
3
Respiratory Protection (Specify Type):
Provide general dilution ventilation to keep exposure to vapors as low as possible. Can wear the mask for organic
solvent when get in touch with high density of vapor.
Ventilation:
LOCAL EXHAUST: Good general ventilation should be used. Use local exhaust ventilation as needed so that exposure
limits are met.
MECHANICAL (GENERAL): Provide general ventilation in possessing and storage areas so that exposure limits are
met.
Engineering Controls: General room ventilation is sufficient during normal use and handling. Do not install these
batteries in sealed, unventilated areas.
Section 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION