Temperatur- und Luftfeuchtigkeitssensor – innen S. 1 Temperature and Humidity Sensor – indoor p. 22 Homematic IP Temperatur- und Luftfeuchtigkeitssensor – innen 1 Wechselrahmen 1 Montageplatte 2 Doppelseitige Klebestreifen 2 Schrauben 3,0 x 30 mm 2 Dübel 5 mm 2 1,5 V LR03/Micro/AAA Batterien 1 Bedienungsanleitung Dokumentation © 2016 eQ-3 AG, Deutschland Alle Rechte vorbehalten.
6 4 E I F 3 5 7 G H G H
Inhaltsverzeichnis 1 2 3 4 5 Hinweise zur Anleitung....................................................2 Gefahrenhinweise.............................................................2 Funktion und Geräteübersicht.......................................4 Allgemeine Systeminformationen................................. 5 Inbetriebnahme................................................................. 5 5.1 5.2 6 7 Batterien wechseln.........................................................
Hinweise zur Anleitung 1 Hinweise zur Anleitung Lesen Sie diese Anleitung sorgfältig, bevor Sie Ihre Homematic IP Geräte in Betrieb nehmen. Bewahren Sie die Anleitung zum späteren Nachschlagen auf! Wenn Sie das Gerät anderen Personen zur Nutzung überlassen, übergeben Sie auch diese Anleitung. Benutzte Symbole: Achtung! Hier wird auf eine Gefahr hingewiesen. Hinweis. Dieser Abschnitt enthält zusätzliche wichtige Informationen! 2 Gefahrenhinweise Öffnen Sie das Gerät nicht.
Gefahrenhinweise Betreiben Sie das Gerät nur in trockener sowie staubfreier Umgebung, setzen Sie es keinem Einfluss von Feuchtigkeit, Vibrationen, ständiger Sonnen- oder anderer Wärmeeinstrahlung, Kälte und keinen mechanischen Belastungen aus. Das Gerät ist kein Spielzeug! Erlauben Sie Kindern nicht damit zu spielen. Lassen Sie das Verpackungsmaterial nicht achtlos liegen. Plastikfolien/ -tüten, Styroporteile etc. können für Kinder zu einem gefährlichen Spielzeug werden.
Funktion und Geräteübersicht 3 Funktion und Geräteübersicht Der Homematic IP Temperatur- und Luftfeuchtigkeitssensor – innen misst die Temperatur und Luftfeuchtigkeit im Raum. Die Messwerte werden zyklisch an den Homematic IP Access Point sowie an die Homematic IP App übermittelt und tragen zur Regulierung des Raumklimas bei.
Allgemeine Systeminformationen 4 Allgemeine Systeminformationen Dieses Gerät ist Teil der Raumklimalösung von Homematic IP und kommuniziert über das Homematic IP Funkprotokoll. Alle Geräte des Homematic IP SmartHome-Systems können komfortabel und individuell per Smartphone über die Homematic IP App konfiguriert werden. Welcher Funktionsumfang sich innerhalb des Homematic IP Systems im Zusammenspiel mit weiteren Komponenten ergibt, entnehmen Sie bitte dem Homematic IP Anwenderhandbuch.
Inbetriebnahme bitte dem Homematic IP Anwenderhandbuch (zu finden im Downloadbereich unter www.eQ-3.de). Damit der Temperatur- und Luftfeuchtigkeitssensor in Ihr System integriert werden und mit anderen Homematic IP Geräten kommunizieren kann, muss er zunächst an den Homematic IP Access Point angelernt werden. Zum Anlernen des Temperatur- und Luftfeuchtigkeitssensors gehen Sie wie folgt vor: • Öffnen Sie die Homematic IP App auf Ihrem Smartphone. • Wählen Sie den Menüpunkt „Gerät anlernen“ aus.
Inbetriebnahme • • • • • 5.2 scannen Sie den QR-Code. Die Gerätenummer finden Sie auf dem Aufkleber im Lieferumfang oder direkt am Gerät. Warten Sie, bis der Anlernvorgang abgeschlossen ist. Zur Bestätigung eines erfolgreichen Anlernvorgangs leuchtet die LED grün. Das Gerät ist nun einsatzbereit. Leuchtet die LED rot, versuchen Sie es erneut. Wählen Sie aus, in welcher Anwendung Sie Ihr Gerät verwenden möchten. Ordnen Sie das Gerät in der App einem Raum zu und vergeben Sie einen Namen für das Gerät.
Inbetriebnahme • mit den mitgelieferten Schrauben an der Wand befestigen. Alternativ können Sie den Temperatur- und Luftfeuchtigkeitssensor auf einer Unterputzdose montieren. 5.2.1 Klebestreifenmontage Um den zusammengesetzten Temperatur- und Luftfeuchtigkeitssensor mit den Klebestreifen zu montieren, gehen Sie wie folgt vor: • Wählen Sie einen beliebigen Montageort aus.
Inbetriebnahme 5.2.2 Schraubmontage Um den Temperatur- und Luftfeuchtigkeitssensor mithilfe der Schrauben zu montieren, gehen Sie wie folgt vor: • Wählen Sie einen geeigneten Montageort aus. Stellen Sie sicher, dass an der gewünschten Position in der Wand keine Leitungen verlaufen! • • • Halten Sie die Montageplatte (D) an die gewünschte Montageposition. Achten Sie darauf, dass der Pfeil auf der Vorderseite der Montageplatte nach oben zeigt.
Inbetriebnahme • 5.2.3 Setzen Sie den Sensor (B) ein (s. Abbildung 1). Achten Sie darauf, dass die Klammern der Montageplatte in die Öffnungen des Sensors rasten. Montage auf einer Unterputzdose Sie können den Temperatur- und Luftfeuchtigkeitssensor mithilfe der Löcher (G) auf einer Unterputz-/Installationsdose montieren (s. Abbildung 5). In der Unterputzdose dürfen sich keine offenen Leiterenden befinden. Sollten für die Montage bzw.
Inbetriebnahme schwere Sachschäden, z. B. durch Brand. Es droht für Sie die persönliche Haftung bei Personen- und Sachschäden.
Batterien wechseln ist darauf zu achten, dass die Montageplatte des Temperatur- und Luftfeuchtigkeitssensors bündig neben bereits befestigten Montageplatten/Tragringen angebracht und daran ausgerichtet wird. Der Temperatur- und Luftfeuchtigkeitssensor passt in die 55er-Rahmen folgender Hersteller: Hersteller Rahmen Berker S.1, B.1, B.3, B.
Batterien wechseln Um die Batterien des Temperatur- und Luftfeuchtigkeitssensors zu wechseln, gehen Sie wie folgt vor: • In montiertem Zustand lässt sich der Sensor einfach aus dem Rahmen (A) und von der Montageplatte (D) ziehen. Fassen Sie den Sensor (B) seitlich an und ziehen Sie ihn aus dem Rahmen heraus (s. Abbildung 2). Das Öffnen des Gerätes ist nicht erforderlich. • Drehen Sie den Sensor auf die Rückseite, um die Batterien zu entnehmen.
Fehlerbehebung ben oder einen gleichwertigen Typ. Batterien dürfen niemals aufgeladen werden. Batterien nicht ins Feuer werfen. Batterien nicht übermäßiger Wärme aussetzen. Batterien nicht kurzschließen. Es besteht Explosionsgefahr! Verbrauchte Batterien gehören nicht in den Hausmüll! Entsorgen Sie diese in Ihrer örtlichen Batteriesammelstelle! 7 Fehlerbehebung 7.
Fehlerbehebung eine Funkstörung sein (s. „10 Allgemeine Hinweise zum Funkbetrieb“ auf Seite 19). Die fehlerhafte Übertragung kann folgende Ursachen haben: • Empfänger nicht erreichbar, • Empfänger kann Befehl nicht ausführen (Lastausfall, mechanische Blockade etc.) oder • Empfänger defekt. 7.3 Duty Cycle Der Duty Cycle beschreibt eine gesetzlich geregelte Begrenzung der Sendezeit von Geräten im 868-MHz-Bereich.
Fehlerbehebung 7.4 Fehlercodes und Blinkfolgen Blinkcode Bedeutung Kurzes oranges Blinken Funkübertra- Warten Sie, bis gung/Sendie Übertragung deversuch/ beendet ist. Datenübertragung 1x langes grünes Leuchten Vorgang bestätigt Sie können mit der Bedienung fortfahren. 1x langes rotes Leuchten Vorgang fehlgeschlagen Versuchen Sie es erneut (s. „7.2 Befehl nicht bestätigt“ auf Seite 14).
Fehlerbehebung Kurzes oranges Blinken (alle 10 s) Anlernmodus aktiv Geben Sie die letzten vier Ziffern der GeräteSeriennummer zur Bestätigung ein (s. „5.1 Anlernen“ auf Seite 5). 1x langes rotes Leuchten Vorgang fehlgeschlagen oder DutyCycle-Limit erreicht Versuchen Sie es erneut („7.2 Befehl nicht bestätigt“ auf Seite 14 oder „7.3 Duty Cycle“ auf Seite 15). 6x langes rotes Blinken Gerät defekt Achten Sie auf die Anzeige in Ihrer App oder wenden Sie sich an Ihren Fachhändler.
Wiederherstellung der Werkseinstellungen 8 Wiederherstellung der Werkseinstellungen Die Werksteinstellungen des Gerätes können wiederhergestellt werden. Dabei gehen alle Einstellungen verloren. Um die Werkseinstellungen des Temperatur- und Luftfeuchtigkeitssensors wiederherzustellen, gehen Sie wie folgt vor: • Fassen Sie den Sensor (B) seitlich an und ziehen Sie ihn aus dem Rahmen heraus (s. Abbildung 2). • Entnehmen Sie eine Batterie.
Wartung und Reinigung 9 Wartung und Reinigung Das Gerät ist für Sie bis auf einen eventuell erforderlichen Batteriewechsel wartungsfrei. Überlassen Sie eine Wartung oder Reparatur einer Fachkraft. Reinigen Sie das Gerät mit einem weichen, sauberen, trockenen und fusselfreien Tuch. Für die Entfernung von stärkeren Verschmutzungen kann das Tuch leicht mit lauwarmem Wasser angefeuchtet werden.
Technische Daten Hiermit erklärt die eQ-3 AG, dass sich dieses Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. Die vollständige Konformitätserklärung finden Sie unter www.eQ-3.de. 11 Technische Daten Geräte-Kurzbezeichnung: Versorgungsspannung: Stromaufnahme: Batterielebensdauer: Schutzart: Umgebungstemperatur: Abmessungen (B x H x T): Ohne Rahmen: Mit Rahmen: Gewicht: Funkfrequenz: Empfängerkategorie: Typ.
Technische Daten Entsorgungshinweis Gerät nicht im Hausmüll entsorgen! Elektronische Geräte sind entsprechend der Richtlinie über Elektro- und Elektronik-Altgeräte über die örtlichen Sammelstellen für Elektronik-Altgeräte zu entsorgen. Konformitätshinweis Das CE-Zeichen ist ein Freiverkehrszeichen, das sich ausschließlich an die Behörden wendet und keine Zusicherung von Eigenschaften beinhaltet. Bei technischen Fragen zum Gerät wenden Sie sich bitte an Ihren Fachhändler.
Package contents Quantity Description 1 Homematic IP Temperature and Humidity Sensor - indoor 1 Clip-on frame 1 Mounting plate 2 Double-sided adhesive strips 2 Screws 3.0 x 30 mm 2 Plugs 5 mm 2 1.5 V LR03/micro/AAA batteries 1 Operating manual Documentation © 2016 eQ-3 AG, Germany. All rights reserved.
Table of contents 1 2 3 4 5 Information about this manual....................................24 Hazard information.........................................................24 Function and device overview.....................................26 General system information.........................................27 Start-up.............................................................................27 5.1 5.2 5.3 6 7 Replacing batteries.........................................................
Information about this manual 1 Information about this manual Please read this manual carefully before beginning operation with your Homematic IP components. Keep the manual so you can refer to it at a later date if you need to. If you hand over the device to other persons for use, please hand over this manual as well. Symbols used: Attention! This indicates a hazard. Please note: This section contains important additional information. 2 Hazard information Do not open the device.
Hazard information The device may only be operated in dry and dustfree environment and must be protected from the effects of moisture, vibrations, solar or other methods of heat radiation, cold and mechanical loads. The device is not a toy; do not allow children to play with it. Do not leave packaging material lying around. Plastic films/bags, pieces of polystyrene, etc. can be dangerous in the hands of a child.
Function and device overview 3 Function and device overview The Homematic IP Temperature and Humidity Sensor - indoor measures the temperature and humidity in the room. The measured values are transferred cyclically to the Homematic IP Access Point as well as to the Homematic IP app and help to regulate the room climate. Take a look at the homescreen of the app and you will be informed about the temperature as well as the current humidity of the corresponding room.
General system information 4 General system information This device is part of the climate control solution of Homematic IP and works with the Homematic IP radio protocol. All devices of the Homematic IP smart home system can be configured comfortably and individually with a smartphone via the Homematic IP app. The available functions provided by the Homematic IP system in combination with other components are described in the Homematic IP User Guide.
Start-up To integrate the temperature and humidity sensor into your system and enable it to communicate with other Homematic IP devices, you must teach-in the device to your Homematic IP Access Point first. To teach-in the temperature and humiditiy sensor, please proceed as follows: • Open the Homematic IP app on your smartphone. • Select the menu item “Teach-in device”. • To remove the sensor (B) from the frame, take hold of the sides of the sensor and pull it out (see figure 2). • Turn over the sensor.
Start-up • • • • • 5.2 Please wait until teach-in is completed. If teaching-in was successful, the LED lights up green. The device is now ready for use. If the LED lights up red, please try again. Please select in which application you want to use the device. Allocate the device to a room and give the device a name. Mounting Please read this entire section before starting to mount the device.
Start-up 5.2.1 Adhesive strip mounting For mounting the assembled device with adhesive strips, please proceed as follows: • Choose a site for installation. Make sure that the mounting surface is smooth, solid, non-disturbed, free of dust, grease and solvents and not too cold to ensure long-time adherence. • • • 5.2.2 Fix the adhesive strips (E) on the back side of the mounting plate (D) in the provided area. You should be able to read the letters on the back side (F) (see figure 4).
Start-up Make sure that no electricity or similar lines run in the wall at this location! • • • Position the mounting plate (D) on the desired site on the wall. Make sure that the arrow on the mounting plate is pointing upwards. Use a pen to mark the positions of bore holes (H) (diagonally opposite) in the mounting plate on the wall (see figure 5). Now drill the bore holes. If you are working with a stone wall, drill the marked two 5 mm holes and insert the plugs supplied.
Start-up If the device is mounted to a flush-mounting box, there may be no open conductor ends. If changes or works have to be made on the house installation (e.g.
Start-up • • • • • • • The “5 safety rules” to be used: Disconnect from mains; Safeguard from switching on again; Check that system is deenergised; Earth and short circuit; Cover or cordon off neighbouring live parts; Select suitable tool, measuring equipment and, if necessary, personal safety equipment; Evaluation of measuring results; Selection of electrical installation material for safeguarding shut-off conditions; IP protection types; Installation of electrical installation material; Type of supply n
Replacing batteries Manufacturer Frame Berker S.1, B.1, B.3, B.7 glass ELSO Joy GIRA System 55, Standard 55, E2, E22, Event, Esprit merten 1-M, Atelier-M, M-Smart, M-Arc, M-Star, M-Plan JUNG A 500, AS 500, A plus, A creation 6 Replacing batteries If an empty battery is displayed via the app or the device (see „7.4 Error codes and flashing sequences“ on page 38), replace the used batteries by two new LR03/ micro/AAA batteries. You must observe the correct battery polarity.
Replacing batteries • • • • Turn the sensor over to remove the batteries. Insert two new 1.5 V LR03/micro/batteries into the battery compartment, making sure that you insert them the right way round (see figure 7). Put the sensor back into the frame. Make sure that the clips on the mounting plate latch into the openings on the sensor. Please pay attention to the flashing signals of the device LED while inserting the batteries (see „7.4 Error codes and flashing sequences“ on page 38).
Troubleshooting 7 Troubleshooting 7.1 Weak battery Provided that the voltage value permits it, the temperature and humidity sensor will remain ready for operation also if the battery voltage is low. Depending on the particular load, it may be possible to send transmissions again repeatedly, once the batteries have been allowed a brief recovery period. If the voltage drops too far during transmission, this will be displayed on the device or via the Homematic IP app (see „7.
Troubleshooting 7.3 Duty cycle The duty cycle is a legally regulated limit of the transmission time of devices in the 868 MHz range. The aim of this regulation is to safeguard the operation of all devices working in the 868 MHz range. In the 868 MHz frequency range we use, the maximum transmission time of any device is 1% of an hour (i.e. 36 seconds in an hour). Devices must cease transmission when they reach the 1% limit until this time restriction comes to an end.
Troubleshooting 7.4 Error codes and flashing sequences Flashing code Meaning Solution Short orange flashing Radio transmission/ attempting to transmit/data transmission Wait until the transmission is completed. 1x long green lighting Transmission confirmed You can continue operation. 1x long red lighting Transmission failed Please try again (s. „7.2 Command not confirmed“ on page 36).
Troubleshooting 1x long red lighting Transmission failed or duty cycle limit is reached Please try again (see sec. „7.2 Command not confirmed“ on page 36 or „7.3 Duty cycle“ on page 37). 6x long red flashing Device defective Please see your app for error message or contact your retailer. 1x orange and 1 x green lighting (after inserting batteries) Test display Once the test display has stopped, you can continue.
Restore factory settings 8 Restore factory settings The factory settings of the device can be restored. If you do this, you will lose all your settings. To restore the factory settings of the temperature and humidity sensor please proceed as follows: • To remove the sensor (B) from the frame, take hold of the sides of the sensor and pull it out (see figure 2). • Remove a battery.
Maintenance and cleaning 9 Maintenance and cleaning The device does not require you to carry out any maintenance other than replacing the battery when necessary. Enlist the help of an expert to carry out any maintenance or repairs. Clean the device using a soft, lint-free cloth that is clean and dry. You may dampen the cloth a little with lukewarm water in order to remove more stubborn marks. Do not use any detergents containing solvents, as they could corrode the plastic housing and label.
Technical specifications eQ-3 AG hereby declares that this device complies with the essential requirements and other relevant regulations of Directive 1999/5/EC. You can find the full declaration of conformity at www.eQ-3.de. 11 Technical specifications Device short description: Supply voltage: Current consumption: Battery life: Degree of protection: Ambient temperature: Dimensions (W x H x D): Without frame: Including frame: Weight: Radio frequency: Receiver category: Typ.
Technical specifications Instructions for disposal Do not dispose of the device with regular domestic waste! Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Electronic Equipment Directive. Information about conformity The CE sign is a free trading sign addressed exclusively to the authorities and does not include any warranty of any properties. For technical support, please contact your retailer.
Technical specifications 44