operation manual

43
Technical specifications
Installation: only in switch boxes
(device boxes) in
accordance with DIN
49073-1 or junction
boxes (surface-mounting
boxes) in accordance
with DIN 60670-1
Degree of protection: IP20
Measurement category: CAT III
Ambient temperature: -10 to +55 °C
Dimensions (W x H x D): 54 x 33 x 41 mm
Weight: 45 g
Radio frequency band: 868.0-868.6 MHz
869.4-868.65 MHz
Maximum radiated power: 10 dBm
Receiver category: SRD category 2
Typ. open area RF range: 130 m
Duty cycle: < 1 % per h/< 10 % per h
Subject to technical changes.