User manual

Start-up
41
Wireless smoke alarms that have been taught-in to a group
already cannot be taught-in to another group. Two groups cannot
be connected to each other. Teaching-in can not be performed
and will be indicated by red ashing of the LED. Therefore, a
factory reset has to be performed for all devices of a group (see
sec. “Restore factory settings” on page 54). Afterwards, the
wireless smoke alarms can be taught-in separately to the group
as described above.
After the wireless smoke alarms have been taught-in successfully, the
devices can be mounted (see sec. “Mounting the wireless smoke alarm”
on page 47).
6.1.2 Teaching-in to a Homematic Central Control Unit
Your device can be conveniently
connected directly to other devices or
used in central control unit programs
by using the Homematic software “WebUI”. New devices are taught-in to
the CCU via the Homematic “WebUI”.
A group of multiple taught-in smoke alarms remains unchanged if
the devices have been taught-in to a central control unit as well.
Additional smoke alarm can be taught-in to this group only via the
central control unit or you need to perform a factory reset for all
devices of the group (see sec. “7.6 Restore factory settings” on
page 54).
Each component can only be taught-in to one CCU.
If several Homematic Wireless Smoke Alarms are used in
connection with a Central Control Unit, all devices have to be
taught-in to the Central Control Unit before installation.