Operation Manual
25
3.1.2 Connections, fuse, miscellaneous
(H) – Fuse for siren/ashing output
(I) – Terminals for siren, ashing light, tamper signal:
KL 1: Input for signalling device’s tamper contact
KL 2: 12 V output for siren connection
KL 3: 12 V output for ashing light connection
(J) – Tamper contact
(K) – Mains connection KL 4
(L) – Lead gel battery to provide back-up in the event of a mains
supply failure
L
I
KL1KL2KL3
KL4
SI1
S1
TA1
TA2
D8
D9
D10
K
J
H